background image

 
 

 

Replace fuse only with the same type. 

 

In the event of serious operating problem, stop using the unit immediately. 

 

The housing, the lenses must be replaced if they are visibly damaged. 

 

DO NOT open the unit as there are no user serviceable parts inside. Never try to repair the unit 

by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please 

contact the nearest authorized technical assistance center.   

 

Disconnect the mains power if the fixture is not used for a long time. 

 

DO use original packing materials once transport it again. 

 
 
 
 
 

 

Installation:   

The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is 

firmly fixed to avoid vibration and slipping while operating. Always ensure that the structure to 

which you are attaching the unit is secure and is able to support a weight of 10 times of the 

unit’s weight. Also always use a safety cable that can hold 12 times of the weight of the unit 

when installing the fixture in the air.   

 

The equipment must be fixed by professionals. And it must be fixed at a place where is out of the 

touch of people and has no one pass by or under it. 

 

If using a 230V 50Hz power supply, DO NOT connect in series more than 18 units; use 
another main supply for the next 18 fixtures. 
If using a 120V 60Hz power supply, DO NOT connect in series more than 9 units; use 
another main supply for the next 9 fixtures. 

 

 

3E 

 

Summary of Contents for Building wash

Page 1: ......

Page 2: ...hical Specfications 4 3 How To Set The Fixture 6 3 1 Control Panel 6 3 2 Main Functions 7 4 How To Control The Unit 12 4 1 DMX Controller 12 4 2 DMX 512 Configuration 12 5 DMX512 Connections 14 6 Troubleshooting 15 7 Fixture Cleaning 15 1E ...

Page 3: ...rder to avoid electric shock Maximum ambient temperature Ta 40 Don t operate it where the temperature is higher than this DO NOT connect the device to any dimmer pack Make sure there are no flammable materials close to the unit while operating as it is fire hazard Look over power wires carefully replace immediately if there is any damage Unit surface temperature may reach up to 60 DO NOT touch the...

Page 4: ...ed via its screw holes on the bracket Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit s weight Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture in the air The equ...

Page 5: ...t applications for the illumination of buildings bridges stadium landscapes theme parks and more Key Facts Die cast housing and thermal control for the reliable performance 17000 Lumen Output 1 KHz refreshing frequency flicker free under HD camera Barn door is available upon request sold separately BW 903 CW AR Input Voltage AC 100 240V 50 60Hz Power Consumption 267W Light Source 90 3W CREE Cold W...

Page 6: ...300lm Color Temperature 2900 3200K IP Rating IP66 Weight 15 6Kgs Dimension 385 400 195mm BW 903 VW AR Input Voltage AC 100 240V 50 60Hz Power Consumption 267W Light Source 42 3W CREE Warm White and 48 3W Cold White LEDs Beam Angle 6 15 25 40 60 80 Lumen Output 17300lm Color Temperature 2900 5900K IP Rating IP66 Weight 15 6Kgs Dimension 385 400 195mm 5E ...

Page 7: ...go backward in the selected functions 4 UP To go forward in the selected functions 5 ENTER To confirm the selected functions 6 POWER IN Water proof connectors for power input 7 POWER OUT Water proof connectors for power output 8 DMX IN Water proof 3 pin XLR connectors for DMX 512 operation 9 DMX OUT Water proof connectors for DMX 512 operation with 3 pin XLR plug 6E ...

Page 8: ...display will blink Use the DOWN and UP button to change the mode Once the required mode has been selected press the ENTER button to setup or it will automatically return to the main functions without any change after idling one minute Back to the functions without any change press the MENU button The main functions are shown below BW 903 CW AR BW 903 WW AR 7E ...

Page 9: ...BW 903VW AR 8E ...

Page 10: ...back to the functions without any change press the MENU button Color Temperature Adjusting For BW 903 VW AR only Select the press the ENTER button and the display will blink Use the DOWN and UP button to select the Cool White or Warm White Mode Press the ENTER button to setup and use the DOWN and UP button to adjust the LED brightness between and Once select press the ENTER button to setup or auto...

Page 11: ...automatically return to the main functions without any change after one minute To go back to the previous functions without any change press the MENU button LED Press the MENU button up to when the is shown on the display Pressing ENTER button and the display will blink Use the DOWN and UP button to select display on or display off 20 seconds after exit menu mode Once select press ENTER button to ...

Page 12: ...l show the number of working hours of the unit To go back to the functions press the MENU button Software version Press the MENU button up to when the is blinking on the display Pressing ENTER button and the display will show the version of software of the unit To go back to the functions press the MENU button again 11E ...

Page 13: ...X controller to control the units you have to set DMX address from 1 to 512 channel so that the units can receive DMX signal Press the MENU button up to when the is showing on the display Pressing the NTER button and the display will blink Use the DOWN and UP button to change the DMX512 address Once the address has been selected press and keep the ENTER button pressed up to when the display stops ...

Page 14: ...BW 903 WW AR BW 903 VW AR 13E ...

Page 15: ...the signal and shut down the system 3 The DMX output and input connectors are pass through to maintain the DMX circuit when one of the units power is disconnected 4 Each lighting unit needs to have an address set to receive the data sent by the controller The address number is between 0 511 usually 0 1 are equal to 1 5 The end of the DMX 512 system should be terminated to reduce signal errors 6 3 ...

Page 16: ...the controller check the address settings and DMX polarity 3 If you have intermittent DMX signal problems check the cables of the fixture or the previous one 4 Try another DMX controller C Some fixtures don t respond to the easy controller 1 You may have a break in the DMX cabling Check the LED for the response of the master slave mode signal 2 Wrong DMX address in the unit Set the correct address...

Page 17: ...g frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the fixture s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days 16E ...

Page 18: ...17E ...

Page 19: ... the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55103 1 2009 EN55103 2 2009 EN62471 2008 EN61000 3 2 2006 A1 2009 A2 2009 EN61000 3 3 2008 Harmonized Standard EN60598 2 17 1989 A2 1991 EN60598 1 2008 A11 2009 EN 62471 2008 EN 62493 2010 Safety of household and similar electrical appliances Part 1 General requirements 18E ...

Page 20: ...Innovation Quality Performance ...

Reviews: