To select the
Color Offset
, press the
ENTER
button to show the
COLOR OFFSET
on the display.
Use the
DOWN
and
UP
button to adjust the value from -127 to 127, press the
ENTER
button to
store. Press the
MENU
button to exit.
GOBO OFFSET
—Gobo home position adjustment
To select the
Gobo 1 Offset
, press the
ENTER
button to show the
GOBO OFFSET
on the display.
Use the
DOWN
and
UP
button to adjust the value from -127 to 127, press the
ENTER
button to
store. Press the
MENU
button to exit.
Prism OFFSET
—Prism home position adjustment
To select the
Prism Offset
, press the
ENTER
button to show the
PRISM OFFSET
on the display.
Use the
DOWN
and
UP
button to adjust the value from 0 to 255, press the
ENTER
button to store.
Press the
MENU
button to exit.
4.3 Error Information
Lamp Startup Fail
It appears when there is no lamp or some wires are damaged.
Temperature Sense Error
It appears when temperature check board is damaged.
Lamp Too Hot Power Off
It appears when temperature is detected higher than 110
℃
. Check if the unit is properly ventilated,
or fans or temperature check board may is damaged.
Lamp Too Hot Low Power
It appears when temperature is detected higher than 105
℃
, the unit will run on a low power level.
Maintenance Fixture
It appears when the maintenance remaining time becomes 0S, please enter menu mode and reset
the time.
Lamp On Over 700 Hour
It appears when the lamp has been on over 700 hours, please turn off the lamp.
Memory Initial Fail
It appears when the memory IC is damaged.
11A