background image

 
 

To select the 

Color Offset

, press the 

ENTER

 button to show the 

COLOR OFFSET

 on the display. 

Use the 

DOWN

 and 

UP

 button to adjust the value from -127 to 127, press the 

ENTER

 button to 

store. Press the 

MENU

 button to exit. 

GOBO OFFSET 

—Gobo home position adjustment 

To select the 

Gobo 1 Offset

, press the 

ENTER

 button to show the 

GOBO OFFSET

 on the display. 

Use the 

DOWN

 and 

UP

 button to adjust the value from -127 to 127, press the 

ENTER

 button to 

store. Press the 

MENU

 button to exit. 

Prism OFFSET 

—Prism home position adjustment 

To select the 

Prism Offset

, press the 

ENTER

 button to show the 

PRISM OFFSET

 on the display. 

Use the 

DOWN

 and 

UP

 button to adjust the value from 0 to 255, press the 

ENTER

 button to store. 

Press the 

MENU

 button to exit. 

 

  4.3 Error Information   

Lamp Startup Fail 

It appears when there is no lamp or some wires are damaged. 

Temperature Sense Error 

It appears when temperature check board is damaged. 

Lamp Too Hot Power Off 

It appears when temperature is detected higher than 110

. Check if the unit is properly ventilated, 

or fans or temperature check board may is damaged. 

Lamp Too Hot Low Power 

It appears when temperature is detected higher than 105

, the unit will run on a low power level. 

Maintenance Fixture 

It appears when the maintenance remaining time becomes 0S, please enter menu mode and reset 

the time. 

Lamp On Over 700 Hour 

It appears when the lamp has been on over 700 hours, please turn off the lamp. 

Memory Initial Fail 

It appears when the memory IC is damaged. 

11A 

 

Summary of Contents for AE-610 BEAM

Page 1: ...AE 610 BEAM User Manual Please read the instruction carefully before use...

Page 2: ...3 1 Control Panel 5 4 How To Set The Unit 5 4 1 Main Function 5 4 2 Home Position Adjustment 10 4 3 Error Information 11 5 Control By Universal DMX Controller 12 5 1 Connection 12 5 2 Address Setting...

Page 3: ...f power supply matches the power requirements of the unit It s important to ground the yellow green conductor to earth in order to avoid electric shock Maximum ambient temperature TA 40 Don t operate...

Page 4: ...t as there are no user serviceable parts inside Never try to repair the unit by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized...

Page 5: ...Master slave Sound active LCD display easy to control One gobo wheel One color wheel Smooth 0 100 dimming and variable strobe speeds Voltage AC 100 240V 50 60Hz Power Consumption 190W LED OSRAM SIRIUS...

Page 6: ...ly power 7 DMX In out Water proof cable with 3 pin XLR connectors for DMX 512 operation 4 How To Set The Unit 4 1 Main Function Turn on the unit press the MENU button into menu mode press the UP and D...

Page 7: ...6A...

Page 8: ...ct the Slave 1 normal or Slave 2 2 light show mode Once the mode has been selected press the ENTER button to setup to go back to the functions without any change press the MENU button again Press and...

Page 9: ...t Inverse press the ENTER button to show the TILT INVERSE on the display Use the DOWN UP button to select the Inverse tilt inversion or Normal normal mode Once the mode has been selected press the ENT...

Page 10: ...amp Power On To select Lamp Power On press the ENTER button to show the LAMP POWER ON on the display Use the DOWN UP button to select the On Lamp on when power on or Off Lamp off when power off Once s...

Page 11: ...show the PAN OFFSET on the display Use the DOWN and UP button to adjust the value from 127 to 127 press the ENTER button to store Press the MENU button to exit TILT OFFSET Tilt home position adjustmen...

Page 12: ...djust the value from 0 to 255 press the ENTER button to store Press the MENU button to exit 4 3 Error Information Lamp Startup Fail It appears when there is no lamp or some wires are damaged Temperatu...

Page 13: ...e qualified maintenance 5 Control By Universal DMX Controller 5 1 Connection 1 At last unit the DMX cable has to be terminated with a terminator Solder a 120 ohm 1 4W resistor between pin 2 DMX and pi...

Page 14: ...se a universal DMX controller to control the units you have to set DMX address from 1 to 512 so that the units can receive DMX signal Press MENU button to enter menu mode select DMX Functions press EN...

Page 15: ...robe Open 8 000 008 009 016 017 025 026 033 034 042 043 050 051 059 060 067 068 076 077 084 085 093 094 101 102 110 111 118 119 127 128 189 190 193 194 255 COLOR Open Color1 Color2 Color3 Color4 Color...

Page 16: ...ing Gobo13 Shaking Gobo14 Shaking Gobo15 Shaking Rotation Fast Slow Stop Rotation Slow Fast 10 000 007 008 255 PRISM No Effect Prism Effect 11 000 127 128 189 190 193 194 255 R PRISM Index 0 360 Rotat...

Page 17: ...hannel check the address settings and DMX polarity 3 If you have intermittent DMX signal problems check the pins on connectors or on PCB of the unit or the previous one 4 Try to use another DMX contro...

Page 18: ...would cause malfunction of the fixture Cleaning The cleaning of internal and external optical lenses and or mirrors must be carried out periodically to optimize light output Cleaning frequency depend...

Page 19: ...cordance with the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55103 1 2009 A1 2012 EN55103 2 2009 EN61000 3 2 2014 EN61000 3 3 2013 Harmonized Standard EN 60598 1 2015 EN...

Page 20: ...Innovation Quality Performance 19A...

Reviews: