INSTALLATION INTRUCTIONS
1)
Drill a 10 mm diameter hole 5 cm from the
centre of the shutter’s shaft (see fig. l);
2)
Remove the M 10 t.e. screws from the
gear of the gearmotor.
3)
Remove the two semi-gears by unscrewing
the two M 8 screws (using a 6 mm hexagonal
wrench);
4)
Carefully remove, avoiding any folding, the
black plastic roller carrier bandi;
5)
Separate the two elements of the gearmo-
tor (upper and lower body) acting on the four
M 8 screws (using a 6 mm hexagonal wrench);
6)
Should the shutter shaft be less than 60 mm
long, use the dedicated reducing sockets posi-
tioning them using the previously drilled 10
diameter mm hole as a reference (point 1);
7)
Join the upper and lower bodies using the
four M8 screws removed before;
8)
Tighten the M 10 t.e. screw without hexa-
gon nut using a 17 mm wrench and ensure it
enters the shutter shaft via the 10 mm hole
(previously drilled);
9)
Install the roller band in its appropriate
housing;
10)
Apply the semi-gears, holding them with
the two M 8 screws;
11)
Tighten the M 10 t.e. screw with nut so as
to block the gearmotor on the shaftand tigh-
ten said nut;
12)
Place the last canvas of the shutter on the
shaft and drill a 12 mm diameter hole at the
same location as the M10 threaded hole on
the gear;
13)
Tighten by hand the gear by 1-1
1
/
2
turns by
bringing the grip towards microswitch 1
(down) fig. 1 (It must turn easily);
14)
Lock the shutter to the gearmotor using
the M 10 t.e. screw with washer (using a 17
mm wrench);
15)
Make the electrical connections described
in page 7 passing the 4xl mm cable supplied in-
side the shutter shaft avoiding any contact
with the rotating pars;
16)
After having installed the mechanical parts
and electrical contacts, proceed to regulate
the end of travel;
17)
Turn the end of travel grip by hand uniti-
you hear the click of the microswitch’s trigger
(down regulation completed);
18)
Turn the other grip towards micro-
switch II (up). Switch on current to the gear-
motor via the key selctor or button to en-
sure that when rising the shutter stops at
the correct point to regulate the position,
adjust the grip, using solely and exclusively
the electric commands taking all precautions
to avoid manual lifting.
19)
Should the shutter need to be installed
contrary to the description in fig. 1, the steps
described above should be carried out to the
contrary as microswitch II will stop the de-
scent and microswitch 1 will stop the opening.