5.6
Signal Timing Specification(Between PanelLink & Timing
Controller)
Parameter
Symbol
Value
Units
Notes
Min.
Typ.
Max.
Main
Clock
Frequency
High duration
Low duration
Rise Time
Fall Time
f
CLK
(=1/t
CLK
)
t
wcH
t
wcL
t
rCLK
t
fCLK
54
0.4 t
CLK
0.4 t
CLK
-
-
54
0.5 t
CLK
0.5 t
CLK
-
-
54
0.6 t
CLK
0.6 t
CLK
2.3
1.4
MHz
ns
ns
ns
ns
Dclk :
108MHz
Data
Set-up duration
Hold duration
Rise Time
Fall Time
t
SD
t
HD
t
Dr
t
Df
5.0
5.0
-
-
-
-
-
-
-
-
4.5
2.1
ns
ns
ns
ns
for f
CLK
for f
CLK
C
L
=15pF
C
L
=15pF
Hsync
Period
Pulse Width
Rise/Fall Time
t
HP
t
WH
t
Hr,
t
Hf
12.6
680
8
-
15.63
844
56
-
-
-
-
5
℃
clock
clock
ns
Vsync
Period
Pulse Width
Rise/Fall Time
t
VP
t
WV
t
Vr,
t
Vr
1032
2
-
16.661
1066
3
-
-
-
-
10
msec
lines
lines
ns
Data
Enable
Set-up duration
Hold duration
Horizontal Back Porch
Horizontal Active
Horizontal Front porch
Vertical Back Porch
Vertical Active
Vertical Front porch
Rise/Fall Time
t
SI
t
HI
_
t
HBP
t
HFP
t
VBP
t
VFP
t
Ir,
t
If
5
5
8
640
8
1
1024
1
-
-
-
124
640
24
38
1024
1
-
-
-
-
-
-
-
-
-
5
ns
ns
clock
clock
clock
lines
lines
lines
ns
for f
CLK
for f
CLK
Hsync- Clock phase difference
t
HC
t
CLK
-10
-
t
wcL
ns
Hsync-Vsync phase difference
t
HV
-
-
t
HP
-t
WH
ns