background image

 

 

9

 

15 Rue des Marais 44310 ST Philbert de Gd Lieu – Tel. 02 40 59 95 35 – www.acis-france.com 

POMPE SOLUBLOC 2V 

SOLUBLOC 2V PUMP 

 

5.

 

TROUBLESHOOTING 

FAULTS

 

PROBABLE CAUSES

 

SOLUTIONS

 

Weak pump output

 

Sealed turbine

 

Do cleaning.

 

Pressure loss in the suction

 

Avoid: long pipes, numerous elbows, positioning the pump higher than 

the water level, narrow pipes

 

Incorrect voltage

 

Make sure the voltage in your supply corresponds to the value 

specified on the motor data plate

 

The motor

 

stops

 

Motor overheat

 

Make sure the fan grid is free of obstacles (at least 30 cm clearance 
between the wall and the fan)

 

Check (Control) the absorbed intensity

 

Noise/vibration

 

Cavitation

 

See paragraph 6

 

Foreign body (sand, etc)

 

Dismount, clean, reassemble

 

 
 
 

6.

 

MINIMUM OPERATING PRESSURE 

Model

 

Pressure in the 

water column 

height

 

Pression in Bar

 

Pression in grams

 

SOLUBLOC

 

2 V

 

3

 

0.3

 

300

 

 

Explanation: It is vital that you check the pressures specified above when commissioning the pump. In fact, a pressure 
below these minimum values leads to the premature wearing of the pump assembly. 

Setting: Close the delivery valve progressively in order to achieve the minimum pressure that corresponds to your model.  

 

 

Summary of Contents for VIPOOL SOLUBLOC 2V

Page 1: ...10 ST Philbert de Gd Lieu Tel 02 40 59 95 35 www acis france com POMPE SOLUBLOC 2V SOLUBLOC 2V PUMP POMPE SOLUBLOC 2V Manuel de l utilisateur SOLUBLOC 2V PUMP User Manual 10 02 2017 POMPE POUR PISCINE...

Page 2: ...de faire appel un professionnel pour l installation Couper imp rativement l alimentation lectrique de la pompe avant toute intervention Les valeurs limites figurant sur le tableau technique ne doiven...

Page 3: ...te bornes afin d viter toute entr e d eau par le passage du fil 3 3 2 INSTALLATION HYDRAULIQUE Raccorder la pompe au circuit hydraulique l aide des raccords fournis La connexion des tuyaux aux raccor...

Page 4: ...ntage Prendre les pr cautions n cessaire pour viter de se coincer les mains et les pieds Nettoyer et contr ler toutes les pi ces avant leur remontage Imp rativement remplacer les pi ces us es ou endom...

Page 5: ...indiqu e sur la plaque des caract ristiques moteur Le moteur s arr te Surchauffe du moteur V rifier que la grille du ventilateur soit d gag e distance mur ventilateur au moins 30 cm Contr ler l inten...

Page 6: ...ded under any circumstances In the event of a malfunction or failure please contact your nearest manufacturer s representative or the manufacturer s Technical Support Service Hot surface in the area a...

Page 7: ...s must be connected to the couplings and glued in place The delivery pipe must be fitted at a right angle and perfectly centred with respect to the outlets to be connected so as to avoid the pump and...

Page 8: ...ons to avoid trapping your hands or feet Clean and check all parts before reassembling them Replace all worn or damaged parts imperative Make sure the seals are clean and in the correct position We re...

Page 9: ...overheat Make sure the fan grid is free of obstacles at least 30 cm clearance between the wall and the fan Check Control the absorbed intensity Noise vibration Cavitation See paragraph 6 Foreign body...

Page 10: ...aration de conformit ACIS d clare sous sa responsabilit que les produits ACIS sont conformes aux directives europ ennes 2002 95 CE RoHS 2004 108 CE 2006 95 CE et 2006 42 CE WEEE Declaration of conform...

Reviews: