background image

 

 

7

 

15 Rue des Marais 44310 ST Philbert de Gd Lieu – Tel. 02 40 59 95 35 – www.acis-france.com 

POMPE SOLUBLOC 2V 

SOLUBLOC 2V PUMP 

 

Dual speed pump terminal board 

 

 

 

▪ Neither the motor nor any of the live parts must come into contact with water. 

▪ Make sure the electrical wires are sheathed. 

▪ Check the correct positioning of the cable at the terminal board input in order to avoid any water seeping in through 

the wire passage. 

  

 

3.2

 

HYDRAULIC SYSTEM 

▪ Connect the pump to the hydraulic circuit using the couplings provided. 

▪ The pipes must be connected to the couplings and glued in place. 

▪ The delivery pipe must be fitted at a right angle and perfectly centred with respect to the outlets to be connected, 

so  as  to  avoid  the  pump  and  pipe  from  being  subjected  to  external  stresses  which  could  cause  them  to  break, 
irrespective  of  the  assembly  operations.  We  recommend  a  vertical  pipe  length  of  approx.  60cm  to  facilitate  the 
priming of the pump. 

▪ A slight tilt of the suction pipes (2%) will prevent any air pockets from forming. 

3.3

 

OPERATION 

▪ The pump should operate without making any noise or vibrations. 

▪ Check for any leaks on a regular basis. 

▪ Always stop the pump before handling the valve on your filter (6-way) on the swimming pool’s hydraulic circuit. 

 

  

Summary of Contents for VIPOOL SOLUBLOC 2V

Page 1: ...10 ST Philbert de Gd Lieu Tel 02 40 59 95 35 www acis france com POMPE SOLUBLOC 2V SOLUBLOC 2V PUMP POMPE SOLUBLOC 2V Manuel de l utilisateur SOLUBLOC 2V PUMP User Manual 10 02 2017 POMPE POUR PISCINE...

Page 2: ...de faire appel un professionnel pour l installation Couper imp rativement l alimentation lectrique de la pompe avant toute intervention Les valeurs limites figurant sur le tableau technique ne doiven...

Page 3: ...te bornes afin d viter toute entr e d eau par le passage du fil 3 3 2 INSTALLATION HYDRAULIQUE Raccorder la pompe au circuit hydraulique l aide des raccords fournis La connexion des tuyaux aux raccor...

Page 4: ...ntage Prendre les pr cautions n cessaire pour viter de se coincer les mains et les pieds Nettoyer et contr ler toutes les pi ces avant leur remontage Imp rativement remplacer les pi ces us es ou endom...

Page 5: ...indiqu e sur la plaque des caract ristiques moteur Le moteur s arr te Surchauffe du moteur V rifier que la grille du ventilateur soit d gag e distance mur ventilateur au moins 30 cm Contr ler l inten...

Page 6: ...ded under any circumstances In the event of a malfunction or failure please contact your nearest manufacturer s representative or the manufacturer s Technical Support Service Hot surface in the area a...

Page 7: ...s must be connected to the couplings and glued in place The delivery pipe must be fitted at a right angle and perfectly centred with respect to the outlets to be connected so as to avoid the pump and...

Page 8: ...ons to avoid trapping your hands or feet Clean and check all parts before reassembling them Replace all worn or damaged parts imperative Make sure the seals are clean and in the correct position We re...

Page 9: ...overheat Make sure the fan grid is free of obstacles at least 30 cm clearance between the wall and the fan Check Control the absorbed intensity Noise vibration Cavitation See paragraph 6 Foreign body...

Page 10: ...aration de conformit ACIS d clare sous sa responsabilit que les produits ACIS sont conformes aux directives europ ennes 2002 95 CE RoHS 2004 108 CE 2006 95 CE et 2006 42 CE WEEE Declaration of conform...