WARRANTY

The RD2432D Series are covered by ACI’s Two (2) Year Limited Warranty, which is located in the front of ACI’S 
SENSORS & TRANSMITTERS CATALOG or can be found on ACI’s website: www.workaci.com.

W.E.E.E. DIRECTIVE 

At the end of their useful life the packaging and product should be disposed of via a suitable recycling 
centre. Do not dispose of with household waste. Do not burn.

PRODUCT SPECIFICATIONS

24 VAC, 60 Hz (full wave rectified)

300 mA

Screw Terminal Blocks

16 AWG (1.31 mm2) to 26 AWG (0.129 mm2) 

0.37 ft-lb (0.5 Nm) Nominal

32 to 140ºF (0 to 60ºC)

30 to 50% RH, Noncondensing

-4 to 176ºF (-20 to 80ºC), 70% RH

IEEE 802.15.4-2003/2006

900 MHz, Operating Frequency 10 channels between 902 – 928 MHz

Transmitter Power:

 11 dBm  |  

Receiver Sensitivity:

 -11 dBm 

200 – 300 ft horizontally depending on building type and constructions, and typically 

one floor above and below the transceiver vertically  

 

Four (4) SPDT Pilot Duty Relays, Dry Contact

1.0A, 30 VDC @ 104ºF (40ºC), 0.5A, 125 VAC @ 104ºF (40ºC) Resistive

Mechanical:

 5,000,000 operations minimum @ 36K operations/hr

Electrical:

 100,000 operations minimum (under rated load @ 1.8K operations/hr)

(1) SPDT, Dry contact relay, 1.0A, 30 VDC @ 104ºF (40ºC), 0.5A, 125 VAC @ 104ºF (40ºC) 

Resistive

Standard: 

ABS Plastic I UL94-5VA I 

NEMA 4X:

 Polycarbonate Plastic I UL94 HB

Supply Voltage: 

Supply Current:

Connections:

Wire Size:

Terminal Block Torque Rating:

Operating Temperature Range:

Operating Humidity Range:

Storage Temperature Range:

Data Protocol:

RF Characteristics:

Transmission Distance:

Digital Outputs:

Contact Rating:

Relay Durability:

Lost Signal Alarm:

Enclosure Material | Flammability Rating:

Automation Components, Inc.

2305 Pleasant View Road  |  Middleton, WI 53562

Phone:

 1-888-967-5224  |  

Website:

 workaci.com

Page 4

Version: 6.0

I0000691

Summary of Contents for RD2432D Series

Page 1: ... depending on the layout and construction of the building and one floor above and one floor below the transceiver Sensor distance and reliability can be increased with the addition of a RR2552B s repeater PRECAUTIONS SENSORS REPEATERS AND RECEIVERS SHOULD NOT BE INSTALLED IN THE FOLLOWING AREAS INSIDE METAL ENCLOSURE PANEL INSIDE OR IMMEDIATELY NEXT TO ELEVATOR SHAFT ELEVATOR BANKS IN FRONT OF OR ...

Page 2: ...evice powered by the shared transformer Observe polarity when connecting analog outputs to the controller inputs WIRING Connect 24VAC 60Hz to the TB1 terminals using 16 26 twisted pair wire Check all connections before applying power to the unit Select 0 10VDC or 0 5VDC output by moving J4 jumper Using the RD2432D configuration information connect the analog and digital outputs to the appropriate ...

Page 3: ...ion Components Inc 2305 Pleasant View Road Middleton WI 53562 Phone 1 888 967 5224 Website workaci com Page 3 Version 6 0 I0000691 SIDE VIEW TOP VIEW TOP 5 74 145 8mm 8 74 222mm 8 24 209 3mm 4 56 115 8mm Ø0 18 Mounting Holes 8 74 222mm 2 96 75 2mm ...

Page 4: ...y depending on building type and constructions and typically one floor above and below the transceiver vertically Four 4 SPDT Pilot Duty Relays Dry Contact 1 0A 30 VDC 104ºF 40ºC 0 5A 125 VAC 104ºF 40ºC Resistive Mechanical 5 000 000 operations minimum 36K operations hr Electrical 100 000 operations minimum under rated load 1 8K operations hr 1 SPDT Dry contact relay 1 0A 30 VDC 104ºF 40ºC 0 5A 12...

Reviews: