background image

A U X

B G M

KEY

0

+1

+2

+3

+1

+2

+3

+4

+5

+6

db

L

R

MUTE

BBE

L

S T E R E O

R

VO C A L

PAR T N E R

V O C AL
CANCE L

D V D

+4

+5

+6

DVD

AUX

USB

BGM

AUTO

INPUT SELECTOR

SOUND MODE

POWER

KEY C ONTROL

B A L A N C E

T R E B L E

B A S S

D E L A Y

E C H O

R E P E A T

TREBLE

B A S S

M I C 1 V O L

M I C 2 V O L

M I C 3 V O L

H E A D P H O N E

M I C 1

M I C 2

M I C 3

M U S I C V O L

M I C M A S T E R V O L

MUSIC

MIC

U S B

O F F

O N

AUX INPUT

L

R

VIDEO

AM-828 MIXING AMPLIFIER

Power

Mic 1

Mic 2

Mic 3

Mic 1

Mic 2

Mic 3

Mic Treble

Mic Bass

Mic Echo

Music Volume

10

10

10

10

10

+10

-10

+10

-10

3D Sound

On

Off

KM-110

Karaoke Mixer

On

Off

Mic Volume

Power amplifier

Mixer

Player

1) Connect the 

AC POWER ADAPTER

 

to the UHF-1208X receiver’s 

AC INPUT 110V,

 then 

plug the other end of 

AC POWER ADAPTER

 into the 

WALL OUTLET

.

2)Connect one end of a 

 

TO 

 

CABLE 

to the U

 receiver’s 

UNBALANCE 

AUDIO OUTPUT(MIX) 

and the other end to a karaoke mixer, karaoke player or karaoke 

power amplifier  

  microphone input. If you are using the BALANCE AUDIO OUTPUT, 

use a 

XLR to XLR cable

 or

 XLR to 

cable

3)Unscrew the microphones handle  cover(counter-clockwise) to check to see if there are 
batteries. If not, install  batteries into the microphones with the negative and positive end 
of the battery correspond the negative and positive end of the microphone. Screw the 
microphone handle back on(clockwise).

¼"

¼"

HF

-

1208X

¼"

¼" 

.

AC Power adapter cable

¼

" t

¼

" c

a

b

le

Mic. Input

Mic. Input

Mic. Input

Power Outlet

Installation

Quick IR SYNC

(Channel Matching

 

between receiver and microphone)

1) O

 press MANUAL SCAN button  twice in the roll to start auto channel 

scanning process. The whole auto scanning process will be finished around 90 seconds. 
However, you can stop auto scanning anytime by pressing STOP button. Receiver  will 
select the best/cleanest channel from the channels just went thought.
2) Power on the microphone handheld and use its button part to face the IR SYNC laugher 
on the receiver front panel to prepare the next step(IR syncing).
3) On the receiver, press IR SYNC button twice in the roll to start IR syncing process. 
When the receiver LCD screen shows IRING, press microphone button and release 
shortly. If IR SYNC success, the LCD screen will show IR OK. 
4) Please remain the 1st microphone power on before starting the 2nd microphone’s auto 
channel scanning. otherwise receives might  get the same(cleanest) channel for both #1 
and #2 microphone while auto channel scanning.

n the receiver,

7

POWER

OFF

ON

1

2

3

4

5

6

7

8

9

0

MIC1

MIC2

VOL1

VOL2

EC HO

BA SS

TREBLE

DOLBY

D I G I T A L

CD+G

MPEG-4

Playback

DVD MPEG-4 KARAOKE PLAYER

DGX-106

SD/MMC

MINI SD

USB

How to charge your rechargeable batteries

1)Please use rechargeable dock and wireless microphone handheld which comes with the 
package to charge the rechargeable batteries.
2)Please do not recharge the batteries until the batteries is low, while microphone light 
indicated with the flashing red light.
3)When using rechargeable dock charging batteries, the charging indicate light on the 
charging dock will turns red while batteries charging. when rechargeable batteries full , the 
light will turns off.
4.Charging the batteries before it is low will cause the batteries usage life span to shorten.
*Batteries recharging time = 1.5 hours
*Do not charge the batteries if you are not using rechargeable batteries.

Summary of Contents for UHF-1208XR

Page 1: ...ely and to its fullest potential please read this user s manual carefully before operation and keep for future reference www acesonic com The Leader in Professional Equipment UHF 1208XR DUAL DIVERSITY...

Page 2: ...maintenance servicing instructions in the literature accompanying the appliance 1 This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 o...

Page 3: ...manufacturer 23 Wet location marking Apparatus shall not be exposed to dripping or splashing and no objects filled with liquids such as vases shall be placed on the apparatus 1 Read These Instruction...

Page 4: ...08X receiver 1 l Rechargeable Battery 4 Be sure to keep original packaging in case of re shipping is needed l l Antenna 2 l User manual warranty card 1 l Microphone Battery Recharging Dock 1 3 ft male...

Page 5: ...eiver channel 2 Scan use to start auto channel scanning process usually will need about 90 seconds to complete the process after scanning receiver will pick the best channel 3 IR to start IR sync chan...

Page 6: ...ing unit inside which receive the IR signal from receives to complete the IR matching for microphone and receiver 4 Switch button Microphone Operation Channel switching 1 Install batteries into microp...

Page 7: ...cess The whole auto scanning process will be finished around 90 seconds However you can stop auto scanning anytime by pressing STOP button Receiver will select the best cleanest channel from the chann...

Page 8: ...ceiver end and wall outlet end l See page 6 and 7 for more detail l The transmitter is out of range l Microphone switch is off or mute l Microphone volume is turn down l Batteries in the microphone ar...

Page 9: ...ions Receiver Carrier Wave Frequency Range UHF 668 692 MHz Oscillation Mode Phase locked Loop controlled Carrier Wave Stability 10PPM Switching bandwidth 24MHz Frequency Space 250KHz Sensitivity 105dB...

Page 10: ...Information Contact Info 1 Year Manufacturer Warranty Lifetime Tech Support Design in U S A Tech Support Address 161 S 8th Avenue City of Industry CA 91746 3208 USA Website www acesonic com 626 820 0...

Reviews: