- 30 -
5.1.3 Auto color balance adjustment:
(Analog only, it is not required for DVI-D input source)
1. Setup input timing SXGA (1280x1024@75), pattern 42(5-Mosaic pattern with white color
frame) with Analog signals from Chroma video pattern generator.
2. Enter factory mode (press “e-Key” then press “power” button to turn on monitor).
3. Move black cursor into “BURN IN MODE” tag and select “ON” to enable burn-in mode, then
left OSD menu.
4. Press “ Left Key ” button to do white balance for auto color balance adjustment (will get
optimal gain / offset (clamp) values).
5.1.4 Color adjustment:
1. Setup input timing to any preset modes, pattern 41(full white color pattern) with Analog
signals from Chroma video pattern generator.
2. Enter factory mode (press “e-Key” then press “power” button to turn on monitor).
3. Confirm auto color balance adjustment had already been done.
4. Measure each color temperature (Cool&Warm) by Minolta CA-110 (or equivalent equipment).
5. Two methods can be used to adjust RED, GREEN, BLUE value of each color temperature,
Cool&Warm to meet following spec requirement, the 1
st
method is by using external PC and
IIC alignment protocol to do automatic adjustment, and the 2
nd
method is by manually and
must be in factory mode.
X+-
0.283+(-) 0.03
Color temperature
(Cool set on OSD)
Y+-
0.297+(-) 0.03
X+-
0.313+(-) 0.03
Color temperature
(Warm set on OSD)
Y+-
0.329+(-) 0.03
6. Turns off the monitor power.
Summary of Contents for X193HQ Series
Page 18: ... 18 3 9 Packing ...
Page 39: ... 39 5 4 OSD Operation Guide OSD Function Requirements ...
Page 40: ... 40 ...
Page 41: ... 41 ...
Page 42: ... 42 Remark Acer logo must be appeared while power on or suspend ...
Page 52: ... 52 Fig 2 Appearance Description ...
Page 53: ... 53 Appendix 3 Control Board ...
Page 54: ... 54 Appendix 4 Power Board ...
Page 55: ... 55 ...
Page 56: ... 56 Appendix 5 Interface Board ...
Page 57: ... 57 ...
Page 58: ... 58 ...