8
Electrical Requirements
Standard Test Conditions
All tests shall be performed under the following conditions, unless otherwise specified.
Ambient light
:
Dark room
Viewing distance
:
30-50 cm for LCD performance
Warm up time
All specifications
:
>
30 minutes
Measuring equipment
:
Photo detector PR650 w/2
°
Measurement
field
Control temperature
6500
°
K
User brightness control
:
Set to Factory preset value (cut off raster)
User contrast control
:
Set to factory preset value, which allows that the brightest two of
32 linear distributed gray-scales (0
~
700mv) can be
distinguished.
User red/white balance,
Green/white balance and
Blue/white balance control
:
In the center (unless otherwise specified)
AC Supply voltage
:
230V± 5
%
, 50±3Hz
Ambient temperature
:
20+5
℃
Display mode
:
1280x1024 60Hz, all white
Measurement systems
The units of measure stated in this document are listed below:
1 gamma = 1 nano tesla
1 tesla = 10,000 gauss
cm = in x 2.54
Lb = kg x 2.2
Degrees F = [°C x 1.8] + 32
Degrees C = [°F - 32]/1.8
u' = 4x/(-2x + 12y + 3)
v' = 9y/(-2x + 12y + 3)
x = (27u'/4)/[(9u'/2) - 12v' + 9]
y = (3v')/[(9u'/2) - 12v' + 9]
nits = cd/(m2) = Ft-L x 3.426
lux = foot-candle x 10.76
Summary of Contents for X173
Page 1: ...1 Acer X173 Service Guide ...
Page 10: ...10 LCD Panel Specification General Specifications Mechanical Information ...
Page 11: ...11 Optical Specifications ...
Page 12: ...12 Support Timing ...
Page 18: ...18 Installation ...
Page 19: ...19 Attaching Removing the Base ...
Page 21: ...21 Front Panel Control ...
Page 22: ...22 eColor Management OSD ...
Page 23: ...23 How to Adjust a Setting ...
Page 24: ...24 Adjusting the picture ...
Page 25: ...25 ...
Page 26: ...26 ...
Page 33: ...33 Fig 12 Fig 13 ...
Page 40: ...40 Exploded Diagram Model X173 ...
Page 42: ...42 5 Power Board 6 Main Board ...