X1161/X1261
Confidential
3-4
No
Symptom
Procedure
9
Poor Uniformity/
Shadow
- Ensure the projection screen without dirt
- Ensure the projection lens is clean
- Ensure the Brightness is within spec
- Check rod alignment
- Check Engine Module
10
Dead Pixel/Dust
(Out of spec.)
- Ensure the projection screen without dirt
- Ensure the projection lens is clean
- Clean DMD Chip and Engine Module
- Check DMD Chip
- Check Engine Module
11
Garbage Image
- Ensure that the signal cables and source work as well
- Check Main Board
- Check DMD Board
12
Remote Controller
Failed
- Remote Controller
a. Check Battery
b. Check Remote Controller
c. Check IR Sensor Board
d. Check Main Board
13
Function Abnormal
- Do
"
Reset (All data)
"
of the OSD Menu
- Check Main Board
14
Audio Abnormal
(for X1261 only)
- Ensure that the signal cables and source are work as well
- Ensure that your Projector is not in “Mute” mode
- Check Main Board
- Check Speaker
Summary of Contents for X1161 Series
Page 14: ...X1161 X1261 Confidential 1 Remote Control and Control Panel Layout ...
Page 17: ...Confidential 1 11 X1161 X1261 System Block Diagram for X1161 ...
Page 18: ...X1161 X1261 Confidential 1 12 System Block Diagram for X1261 ...
Page 19: ...Confidential 1 13 X1161 X1261 Bottom Cover Dimension ...
Page 81: ...X1161 X1261 Confidential III D C X1261 25 ...
Page 83: ...X1161 X1261 Confidential I D X1161 ...
Page 86: ...X1161 X1261 Confidential VIII IO MODULE X1161 ...
Page 88: ...X1161 X1261 Confidential IO MODULE X1261 ...
Page 91: ...X1161 X1261 Confidential XIII One Fan Module ...
Page 94: ...X1161 X1261 Confidential XVI Assy Engine Module ...