4-4 Test Condition
- Circumstance brightness: Dark room less than 5.0 lux.
- Inspection distance: 1.8m~2.5m functional inspection.
- Screen size: 60 inches diagonal
- After repairing each unit, it should be burn-in (refer to the table below)
Symptom
Run-in Time
Normal repair
2 hours
NFF
4 hours
Auto shutdown
6 hours
- Enter Burn-In Mode
* Cycle setting is based on the defect symptoms. ie: If it is NFF, the run-in time is 4 hours. You have
to set the lamp on for 50 min. and lamp off for 10 min for 4 cycles.
Press power > left > left > Menu
Choose Burn-In Test > enter
Lamp On (Min)
Press right key to adjust the time (50)
Lamp Off (Min)
Press right key to adjust the time (10)
Set burn in cycle
Press right key to adjust the cycle
After setting up the time, choose Burn-In mode and hit enter
Screen Defects (While replacing DMD Chip, DMD Board and Main Board)
< Figure: Zone A &B Definition >
Summary of Contents for X1160 Serie
Page 19: ...X1160 Family X1260 Family Confidential 1 13 X1160P X1160PZ there are two fans ...
Page 20: ...X1160 Family X1260 Family Confidential 1 14 X1260 Refresh X1260 there is only one fan ...
Page 21: ...X1160 Family X1260 Family Confidential 1 15 X1260K Refresh X1260P there are two fans ...
Page 22: ...X1160 Family X1260 Family Confidential 1 16 Bottom Cover Dimension ...
Page 92: ...X1160 Family X1260 Family Confidential IV ASSY ENGINE MODULE X1160 ...
Page 96: ...X1160 Family X1260 Family Confidential VIII ASSY BOTTOM HOUSING MODULE X1160 ...
Page 98: ...X1160 Family X1260 Family Confidential X ASSY LAMP DRIVER MODULE X1160 1 2 3 5 6 4 7 8 9 ...
Page 100: ...X1160 Family X1260 Family Confidential XII ASSY COLOR WHEEL MODULE X1160 1 2 6 3 4 5 ...
Page 103: ...X1160 Family X1260 Family Confidential XV ASSY ENGINE MODULE X1260 ...