Electrical Requirements of V233H
Standard Test Conditions
All tests shall be performed under the following conditions, unless otherwise specified.
Warm up time
>
30 min.
AC supply voltage
230V± 5
%
, 50± 3 Hz
Ambient temperature
20
°
C
±
5
°
C
Humidity
65%
±
20%
Display mode
1920 x 1080, 60 Hz, Pixel Clock
:
148.5MHZ,all white
e-color mode
Set to “User” mode
Contrast control
Set to The value under user mode, which allows that the brightest
two of 32 linear distributed gray-scales (0
~
700mv) can be
distinguished.
Color temperature
6500°K
Brightness control
The value under user mode
Analog Input signal
700 mVss
Picture position and size
Factory preset value,
Viewing angle
90 ° H and V
Viewing distance
40 cm for LCD performance, 20 cm for LCD failures
Ambient illumination
Dark room < 1 cd/m2
Measurement systems
The units of measure stated in this document are listed below:
1 gamma = 1 nano tesla
1 tesla = 10,000 gauss
cm = in x 2.54
Lb = kg x 2.2
Degrees F = [°C x 1.8] + 32
Degrees C = [°F - 32]/1.8
u' = 4x/(-2x + 12y + 3)
v' = 9y/(-2x + 12y + 3)
x = (27u'/4)/[(9u'/2) - 12v' + 9]
y = (3v')/[(9u'/2) - 12v' + 9]
nits = cd/(m2) = Ft-L x 3.426
lux = foot-candle x 10.76
This Manual: http://www.manuallib.com/file/733325
Summary of Contents for V233H Series
Page 2: ...1 Acer V233H Service Guide This Manual http www manuallib com file 733325 ...
Page 13: ...12 Factory Preset Timing of V233H This Manual http www manuallib com file 733325 ...
Page 26: ...25 This Manual http www manuallib com file 733325 ...
Page 27: ...26 This Manual http www manuallib com file 733325 ...