5
Confidential
Inspection Procedure
No
Step
Specification
Procedure
1
Frequency
and Tracking
Eliminate visual
wavy noise by
Rsync,
Frequency or
Tracking
selection.
- Test Signal : please refer to Test Signal Table
- Test Pattern : General 1
- check and see if image sharpness and
focus are well-performed.
- No video noise is allowed.
2
Boundary
Horz. And Vert.
position of video
should be
adjustable to be
the screen
frame.
- Test Signal : please refer to Test Signal Table
- Test Pattern : General 1
- Adjust Resync or Frequency / Tracking /
H. Position / V. Position to the inner of the
screen.
3
Focus
The text in the
corner should be
clear after adjust
the focus ring.
- Test Signal : please refer to Test Signal Table
- Test Pattern : Full Screen
- Adjust the center clearly; meanwhile, one
slightly vague corner in the image is allowed.
4
HDTV
No discolor
- Test Signal : 480P, 1080i (PD100)
- Test Pattern : Master
- Equipment: Quantum Data 802B or
CHROMA2327
*Please refer to page 4~7 to enter Service Mode.
Use 480P signal, smtpe bar pattern to do video
calibration; then, 4:3 screen and 1080i signal. If the
test result was in discoloration or flickering, please
return the unit back to the repair center. (by Model)
5
Color
Performance
1. No image
(discolor)
2. No light
leakage
- Test Signal : please refer to Test Signal Table
- Test Pattern : 64 RGBW Scale Pattern & 32 Grays
Pattern
- Please check and ensure if each color is
normal and distinguishable.
- If not, please adjust color index of the
Engineering Mode.
6
Screen
Uniformity
Should be
compliant with
60%.(Minimum)
- Test Signal : please refer to Test Signal Table
- Test Pattern : Full White Pattern & Full Black
Pattern
- Please check and ensure the unit is under the
spec.
- Please check and see if it's in normal conidtion.
- If not, please return the unit to repair area.
*Please check and see if there are dead
pixels on DMD Chip.
- The total number and distance of dead pixels
should be compliant with the spec.
Note:
(1) Bright Pixel:
Test Pattern: Full Black Pattern
- Please check and ensure that the unit cannot
accept any bright pixel.
- If not, please return the unit to repair area.
(2) Dark Pixel:
Test Pattern: Full White Pattern
- Please check and ensure that the pixel number
should be smaller or amount to 5 pixels.
- If not, please return the unit to repair area.
Summary of Contents for PD100
Page 79: ...20 Confidential PD120 Assy Engine Bottom Cover Module ...
Page 86: ...27 Confidential Exploded Overview D C XD1170D ...
Page 90: ...31 Confidential ASSY BOTTOM HOUSING MODULE XD1170D ...
Page 92: ...33 Confidential ASSY ENGINE TOP COVER MODULE XD1170D ...
Page 94: ...35 Confidential XD1170D PROJECTION DISPLAY PROJECTOR ASSY SYSTEM FAN 80x25 MODULE ...
Page 96: ...37 Confidential Exploded Overview D C XD1270D ...
Page 99: ...40 Confidential ASSY BOTTOM HOUSING MODULE XD1270D ...
Page 101: ...42 Confidential ASSY BOTTOM BASE MODULE XD1270D ...
Page 107: ...48 Confidential ASSY ENGINE TOP COVER MODULE XD1270D ...
Page 109: ...50 Confidential ASSY ENGINE BOTTOM COVER MODULE XD1270D ...
Page 117: ...58 Confidential XD1270D PROJECTION DISPLAY PROJECTOR ...
Page 119: ...60 Confidential Exploded Overview D C XD1150 ...
Page 122: ...63 Confidential ASSY BOTTOM HOUSING MODULE XD1150 ...
Page 125: ...66 Confidential ASSY BOTTOM BASE MODULE XD1150 ...
Page 130: ...71 Confidential ASSY ENGINE BOTTOM COVER XD1150 ...
Page 137: ...78 Confidential Exploded Overview D C XD1250 ...
Page 140: ...81 Confidential ASSY BOTTOM HOUSING MODULE XD1250 ...
Page 143: ...84 Confidential ASSY BOTTOM BASE MODULE XD1250 ...
Page 148: ...89 Confidential ASSY ENGINE BOTTOM COVER XD1250 ...
Page 161: ...7 Confidential The Different Parts between XD1150 and PD100 ...
Page 162: ...Confidential 8 ...
Page 163: ...9 Confidential ...
Page 164: ...Confidential 10 The Different Parts between XD1150 and XD1250 ...
Page 165: ...11 Confidential The Different Parts between XD1250 and PD120 ...
Page 166: ...Confidential 12 ...
Page 167: ...13 Confidential ...