Confidential
4-7
H7530/H7530D
4-7 Calibration
1. PC Calibration
Procedure
- Test equipment: video generator
- Once Main Board is changed. PC Calibration
should be done as well.
(1) Test signal analog: 800 x 600@60Hz
(2) Test Pattern: White (up) Black (down)
- Note
(1) Calibration pattern should be in full screen
mode.
(2) Please press "Power", "Left", "Left" and
"Menu" buttons sequentially to get into
Service Mode.
(3) Choose "Analog Settings", press "Menu"
button to access "PC Calibration" for
correction in Service Mode. When the
message "Success" appears, it means
"PC Calibration" is OK. Choose "Exit"
to leave the Service Mode.
Check pattern
- Test signal: 1080p/60Hz
- Test pattern: 64 gray RGBW
* After finishing ADC adjustment, check 64 gray
RGBW pattern.
Inspection item
- Color saturation
Criteria
- There should not have any lack of RGBW. The
color should appear normal and sort in right order.
- Color levels should be sufficient and normal. (the
unidentified color levels on both left and right sides
should not over 8 color levels.)
2. Video Calibration
Procedure
- Test equipment: video generator
- Once Main Board is changed. Video Calibration
should be done as well.
(1) Test signal: 720p
(2) Test Pattern: SMPTEbar
- Note
(1) Calibration pattern should be in full screen
mode.
SMPTE BAR
64 gray RGBW
White/Black
Summary of Contents for H7530D Series
Page 18: ...Confidential 1 11 H7530 H7530D Remote Control Layout ...
Page 21: ...H7530 H7530D Confidential 1 14 Getting Started Connecting the Projector ...
Page 23: ...H7530 H7530D Confidential 1 16 System Block Diagram for H7530D ...
Page 24: ...Confidential 1 17 H7530 H7530D Bottom Cover Dimension ...
Page 103: ...H7530 H7530D Confidential III ASSY TOP COVER ...
Page 105: ...H7530 H7530D Confidential ASSY BOTTOM MODULE ...
Page 107: ...H7530 H7530D Confidential VII ASSY BOTTOM HOUSING ...
Page 119: ...H7530 H7530D Confidential XIX A K 13 6 17 16 15 18 11 14 8 9 12 1 2 4 7 ...