4-5
H7530/H7530D
Full white
1 pixel is allowed on the frame.
- Adjacent pixels are unacceptable.
- If there is blemish on full black pattern, please
use gray 10 pattern to judge it.
- Ref. Defect specification table
3. Dark Pixel
Procedure
- Test equipment: video generator
- Test signal: 1080p/ 60Hz
- Test Pattern: Full white
Inspection item
- Dark pixels check
Criteria
- The dark pixel should be no more than 5 under
full white pattern.
- Adjacent pixels are unacceptable.
- Ref. Defect specification table
4. Bright Blemish
Procedure
- Test equipment: video generator
- Test signal: 1080p/60Hz
- Test Pattern: Gray 10
Inspection item - Bright blemish check
Criteria
- The bright blemish should be no more than 10
under gray 10 pattern.
- Ref. Defect specification table
5. Dark Blemish
Procedure
- Test equipment: video generator
- Test signal: 1080p/60Hz
- Test Pattern: Blue 60
Inspection item - Dark blemish check
Criteria
- The dark blemish should be no more than 10
under blue 60 pattern.
- Ref. Defect specification table
Gray 10
Blue 60
Summary of Contents for H7530 Series
Page 18: ...Confidential 1 11 H7530 H7530D Remote Control Layout ...
Page 21: ...H7530 H7530D Confidential 1 14 Getting Started Connecting the Projector ...
Page 23: ...H7530 H7530D Confidential 1 16 System Block Diagram for H7530D ...
Page 24: ...Confidential 1 17 H7530 H7530D Bottom Cover Dimension ...
Page 103: ...H7530 H7530D Confidential III ASSY TOP COVER ...
Page 105: ...H7530 H7530D Confidential ASSY BOTTOM MODULE ...
Page 107: ...H7530 H7530D Confidential VII ASSY BOTTOM HOUSING ...
Page 119: ...H7530 H7530D Confidential XIX A K 13 6 17 16 15 18 11 14 8 9 12 1 2 4 7 ...