4-2
H7530/H7530D
< Figure: Zone A, Zone B & Frame (as green line) Definition, Active area = Zone A + Zone B >
4-4 Test Condition
- Circumstance brightness: Dark room less than 2.0 lux.
- Inspection distance: 1.8 m~2.5 m functional inspection.
- Screen size: 60 inches diagonal.
- After repairing each unit, it should be Run-in (refer to the below table).
Symptom
Run-in Time
Normal repair
2 hours
NFF
4 hours
Auto shutdown
6 hours
- Get into Burn-In Mode
* Cycle setting is based on the defect symptoms. ie: If it is NFF, the run-in time is 4 hours. You have
to set the lamp on for 50 min. and lamp off for 10 min for 4 cycles.
Press power→ left → left → menu
Choose BurnIn Test > enter
Lamp On (Min)
Press right key to adjust the time (50)
Lamp Off (Min)
Press right key to adjust the time (10)
Set Burning cycle
Press right key to adjust the cycle
After setting up the time, choose ''Enter Burn In Mode'' and press "Menu" button.
Screen Defects (While replacing DMD Chip, DMD Board, Main Board)
Frame
Summary of Contents for H7530 Series
Page 18: ...Confidential 1 11 H7530 H7530D Remote Control Layout ...
Page 21: ...H7530 H7530D Confidential 1 14 Getting Started Connecting the Projector ...
Page 23: ...H7530 H7530D Confidential 1 16 System Block Diagram for H7530D ...
Page 24: ...Confidential 1 17 H7530 H7530D Bottom Cover Dimension ...
Page 103: ...H7530 H7530D Confidential III ASSY TOP COVER ...
Page 105: ...H7530 H7530D Confidential ASSY BOTTOM MODULE ...
Page 107: ...H7530 H7530D Confidential VII ASSY BOTTOM HOUSING ...
Page 119: ...H7530 H7530D Confidential XIX A K 13 6 17 16 15 18 11 14 8 9 12 1 2 4 7 ...