4-3
H6500
Symptom
Run-in Time
Normal repair
2 hours
NFF
4 hours
Auto shutdown
6 hours
- Get into Burn-In Mode
* Cycle setting is based on the defect symptoms. ie: If it is NFF, the run-in time is 4 hours. You have
to set the lamp on for 50 min. and lamp off for 10 min for 4 cycles.
Note: Please make sure that the hot exhaust airflows from projectors can flow towards the aisle.
Press power→ left → left → menu
Choose Burn In > enter
Lamp On (Min)
Press right key to adjust the time (50)
Lamp Off (Min)
Press right key to adjust the time (10)
Set Burning cycle
Press right key to adjust the cycle
After setting up the time, choose ''Enter into Burn In Mode'' and press "Menu" button.
4-5 Test Inspection Procedure
Update
Change parts
Main
Board Firmware
Color
Wheel
Lamp
Module
Engine
Module EDID
Lamp
Driver
Lamp
Blower
Version Update
v
v
Color Wheel Index
v
v
PC Calibration
v
v
Video Calibration
v
v
Reset Lamp Hour
v
v
OSD Reset
v
v
EDID
v
Re-write Lamp Hour
Usage
v
Reset Default
Language
v
v
v
Rod adjustment
v
Waveform Download
v
Restore Fan Speed
v
v
v
Note: - After changing parts, check the information above table.
- The Default Language and Waveform Download are the same method.
Summary of Contents for H6500 Series
Page 15: ...H6500 Confidential 1 10 Remote Control Layout ...
Page 19: ...H6500 Confidential 1 14 System Block Diagram ...
Page 20: ...Confidential 1 15 H6500 Bottom Cover Dimension ...
Page 94: ...H6500 Confidential ASSY ENGINE MODULE ...
Page 96: ...H6500 Confidential VII ASSY BOTTOM HOUSING MODULE ...
Page 99: ...H6500 Confidential 17 ASSY BOTTOM COVER MODULE ...
Page 104: ...H6500 Confidential XV DP 9 10 ...