4-4 Test Condition
- Circumstance brightness: Dark room less than 2.0 lux.
- Inspection distance: 1.8 m~2.5 m functional inspection.
- Screen size: 60 inches diagonal.
- After repairing each unit, it should be Run-in (refer to the below table).
Symptom
Run-in Time
Normal repair
2 hours
NFF
4 hours
Auto shutdown
6 hours
- Get into Burn-In Mode
* Cycle setting is based on the defect symptoms. ie: If it is NFF, the run-in time is 4 hours. You have
to set the lamp on for 50 min. and lamp off for 10 min for 4 cycles.
Press power→ left → left → menu on remote controller
Choose Burn In > enter
Lamp On (Min)
Press right key to adjust the time (50)
Lamp Off (Min)
Press right key to adjust the time (10)
Set Burning cycle
Press right key to adjust the cycle
After setting up the time, choose ''Enter into Burn In Mode'' and press "Menu" button.
Screen Defects (While replacing DMD Chip, DMD Board, Main Board)
< Figure: Zone A, Zone B, Zone C & Frame (as green line) Definition, Active area=Zone A + Zone B >
Frame
Summary of Contents for EP720
Page 22: ...X1161 X1261 X1161A X1161N X110 H5360 Confidential 1 16 System Block Diagram for X1261 ...
Page 23: ...Confidential 1 17 X1161 X1261 X1161A X1161N X110 H5360 System Block Diagram for H5360 ...
Page 24: ...X1161 X1261 X1161A X1161N X110 H5360 Confidential 1 18 Bottom Cover Dimension ...
Page 85: ...X1161 X1261 X1161A X1161N X110 H5360 Confidential III D C X1261 25 ...
Page 87: ...X1161 X1261 X1161A X1161N X110 H5360 Confidential I D X1161 ...
Page 90: ...X1161 X1261 X1161A X1161N X110 H5360 Confidential VIII IO MODULE X1161 ...
Page 92: ...X1161 X1261 X1161A X1161N X110 H5360 Confidential IO MODULE X1261 ...
Page 95: ...X1161 X1261 X1161A X1161N X110 H5360 Confidential XIII One Fan Module ...
Page 98: ...X1161 X1261 X1161A X1161N X110 H5360 Confidential XVI Assy Engine Module ...
Page 102: ...X1161 X1261 X1161A X1161N X110 H5360 Confidential XX A K ...