G sensor (calibration) & G sensor verification:
Connect PC and Citizen M under the factory image,
Put Citizen M at horizontal balance jig
Open GSensor_PRT Tool profile and execute “GSensor_TOOL.cmd” to calibrate G sensor.
After G sensor calibrating finish, please check ”GSensorResult.txt”, and confirm Pass or Fail
Remark: G sensor PASS criteria:
if -0.1g<x<0.1g , and -0.1g<y<0.1g , and 0.9g<z<1.1g.
it shall pass verification test. * Here g=9.8m/(s*s)