Chapter 4
Intermittent Problems
Intermittent system hang problems can be caused by a variety of reasons that have nothing to do with a
hardware defect, such as: cosmic radiation, electrostatic discharge, or software errors. FRU replacement
should be considered only when a recurring problem exists.
When analyzing an intermittent problem, do the following:
1.
Run the advanced diagnostic test for the system board in loop mode at least 10 times.
2.
If no error is detected, do not replace any FRU.
3.
If any error is detected, replace the FRU. Rerun the test to verify that there are no more errors.
Undetermined Problems
The diagnostic problems does not identify which adapter or device failed, which installed devices are incorrect,
whether a short circuit is suspected, or whether the system is inoperative.
Follow these procedures to isolate the failing FRU (do not isolate non-defective FRU).
NOTE:
Verify that all attached devices are supported by the computer.
NOTE:
Verify that the power supply being used at the time of the failure is operating correctly.
1.
Power-off the computer.
2.
Visually check for damage. If any problems are found, replace the FRU.
3.
Remove or disconnect all of the following devices:
•
Non-Acer devices
•
Printer, mouse, and other external devices
•
Hard disk drive
•
DIMM
•
CD-ROM/Diskette drive Module
4.
Power-on the computer.
5.
Determine if the problem has changed.
6.
If the problem does not recur, reconnect the removed devices one at a time until you find the failing FRU.
7.
If the Issue is still not resolved, see “Online Support Information” on page 175.
Summary of Contents for Aspire Z5600 Series
Page 6: ...VI ...
Page 10: ...X Table of Contents ...
Page 26: ...16 Chapter 1 ...
Page 64: ...54 Chapter 3 5 Lift the Inverter Board clear of the device ...
Page 93: ...Chapter 3 83 4 Connect the cables on either side of the Inverter Board ...
Page 101: ...Chapter 3 91 4 Secure the B CAS Board with three 3 screws ...
Page 105: ...Chapter 3 95 4 Attach the EMI Cable Mylar to the Back Frame as shown ...
Page 108: ...98 Chapter 3 3 Secure the Back Cover using fourteen 14 screws ...
Page 128: ...118 Chapter 5 Bottom View Item Description RTC RTC battery socket ...
Page 144: ...134 Chapter 6 ...
Page 145: ...Chapter 6 135 ...
Page 196: ...Appendix A 186 ...
Page 208: ...198 Appendix C ...