Jumper Setting
The section explains how to set jumper for correct configuration of the mainboard.
Setting Jumper
Use the motherboard jumpers to set system configuration options. Jumpers with more Than one pin are
numbered. When setting the jumpers, ensure that the jumper caps are Placed on the correct pins.
Header Name
Function
Definition
1. I/O connector
PS/2
1 – MS_DATA
2 – NC
3 – GND
4 – PWR
5 – MS_CLK
6 – NC
7 – GND
8 – GND
9 – KB_DATA
10 – NC
11 – GND
12 – PWR
13 – KB_CLK
14 – NC
15 – GND
16 – GND 17 – GND
VGA
1 – RED
2 – GREEN
3 – BLUE
4 – NC
5 – GND
6 – GND
7 – GND
8 – GND
9 – PWR
10 – GND
11 – NC
12 – VGA_DATA
13 – HSYNC
14 – VSYNC
15 – VGA_CLK
16 – GND
17 – GND