Acer
Service Manual
18
5.1.4
Set brightness and contrast to be maximum, apply pattern as Fig.3, it should be the following
requirement:
%
≡
75
)
(backlight
points
nine
of
luminance
Max.
)
(backlight
points
nine
of
luminance
Min.
Fig. 3
5.2
Color Temperature Check
5.2.1
Test mode: 1440x900 @ 60 Hz
5.2.2
Test pattern: pattern #41 of “WHITE”
5.2.3
Test tool: Color Analyzer Chroma7120
5.2.4
Set brightness to be maximum and contrast to be 50%, measure color coordinate and luminance by
color analyzer as the following:
Chromaticity Coordinate
Mode
x
y
9300K
0.283 ± 0.030
0.298 ± 0.030
USER
/
/
6500K
0.313 ± 0.030
0.329 ± 0.030