- 15 -
Notes 5) Definition of Luminance of White : measure the luminance of white at center point.
Notes 6)Definition of 5 points brightness uniformity (Measuring points: Refer to the Note 5)
Bmax
B
UNI
=
Bmin
Bmax: Maximum brightness
Bmin: Minimum brightness
Notes 7) Definition of Flicker level
Flicker Voltage
pp
F =
x 100 %
LMD Voltage
dc
♦
One maximum value of three estimated values.
♦
For this test ,an LMD(Light Measurement Device)is needed with adequate response time to track any
visible rate flicker component and with a voltage level output proportional
To luminance intensity.
♦
Test Pattern: For dot inversion Driving(Gray levels of foreground dots on the test panel
Are G22,G32,and G45)
♦
Test Point :Center point of the display area