Hardware removal and installation
53
5.
(Optional step) Add the front left and right handles to the enclosure using five screws to secure each
handle. Install a thumbscrew through the bottom hole of each handle.
NOTE:
These handles are optional and need only be installed when mounting the system into a short rack.
When mounting into a deep rack, they are unnecessary and regular screws should be used instead of
thumbscrews.
Be aware that these handles are not to be used for lifting the system, they are only to be used to slide the
system within the rack.
6.
With one person on either side (see the descriptive label on the side of the enclosure), lift the enclosure
and slide it into the installed rails.
WARNING:
Be sure that the enclosure is empty of all blades, power supplies, switches and management
modules
BEFORE
lifting. These should be installed
AFTER
the enclosure is mounted in the rack. Injury
and damage may occur if components are not removed from the rack prior to installation.
7.
After pushing the enclosure all the way into the rack, use two roundhead screws on each side of the
server to lock it into place.