Chapter 4
82
Undetermined Problems
The diagnostic problems does not identify which adapter or device failed, which installed devices are incorrect,
whether a short circuit is suspected, or whether the system is inoperative.
Follow these procedures to isolate the failing FRU (do not isolate non-defective FRU).
NOTE:
Verify that all attached devices are supported by the computer.
NOTE:
Verify that the power supply being used at the time of the failure is operating correctly. (See “Power
System Check” on page 70):
1.
Power-off the computer.
2.
Visually check them for damage. If any problems are found, replace the FRU.
3.
Remove or disconnect all of the following devices:
T
Non-Acer devices
T
Printer, mouse, and other external devices
T
Battery pack
T
Hard disk drive
T
DIMM
T
CD-ROM/Diskette drive Module
T
PC Cards
4.
Power-on the computer.
5.
Determine if the problem has changed.
6.
If the problem does not recur, reconnect the removed devices one at a time until you find the failing FRU.
7.
If the problem remains, replace the following FRU one at a time. Do not replace a non-defective FRU:
T
System board
T
LCD assembly
Summary of Contents for 1410 2039 - Aspire
Page 1: ...Aspire 1410 1680 Series Service Guide ...
Page 6: ...VI ...
Page 10: ...IX ...
Page 45: ...Chapter 1 35 ...
Page 69: ...59 Chapter 3 8 Then detach the LCD module from the main unit ...
Page 73: ...63 Chapter 3 ...
Page 77: ...67 Chapter 3 ...
Page 105: ...95 Chapter 6 Exploded Diagram ...
Page 117: ...107 Chapter 6 ...
Page 119: ...109 Appendix A ...
Page 125: ...115 Appendix B ...
Page 127: ...117 Appendix C ...