Technical Data*

Sensor

Semiconductor Sensor

Accuracy

+/- 0.100‰ (per mill) with reference to 0.500‰ at 25°C (per mill = default setting) 

OR +/- 0.010% BAC (Blood Alcohol Concentration) 

with reference to 0.050 % BAC at 25°C

OR +/- 0.500mg/L with reference to 0.250mg/L at 25°C

Detection Range

0.000 to 4.000‰ (per mill)

OR 0.000 to 0.400% BAC (USA)

OR 0.000 to 2.000mg/L (UK) 

Warm-up Time

Within 15 up to 20 seconds at 0.5‰. This may vary depending on the value of per 

mill / BAC which was measured.

Dimension

105 x 50 x 18mm (H x W x D)

Weight

98g (batteries included)

Power Supply

2 pieces of 1.5V AA Alkaline batteries

Working Temperature

10°C to 40°C

Storage Temperature

0°C to 40°C

Calibration

Recommendation: Every 6-12 months or after 300 tests. For a calibration service 

you can send the device to ACE Instruments (see www.alkomat.net).

*The technical data are subject to change without prior notice for functional improvements.

Warranty and Liability

ACE Handels- und Entwicklungs GmbH (ACE Instruments) provides a warranty of two years after purchase for 

material and processing errors of the product (see attached warranty and liability declaration) in all versions 

and designations; and a warranty of one year for the sensor. This warranty includes the electronics as well as 

the  casing  and sensor without  sampling  components. Components  that  inevitably  degrade  over  time  (such 

as fuses) are not part of this warranty. The warranty is valid from the date of delivery or from the date of first 

activation (always the shorter period), if not stated otherwise in the accompanying ACE Instruments product 

literature.

Limitation of Warranty and Liability

1. PRODUCT DESCRIPTION

ACE  Instruments  rejects  any  further  expressly  stated  or  implied  warranty,  including  the  marketability  and 

suitability for a determined purpose. This warranty especially excludes calibration. After changing the sensor, 

calibration is absolutely necessary. If an exchange of the sensor or a calibration is required for a product, the 

user may receive a cost estimate. Should the user reject the estimate, ACE Instruments will send the product 

back unrepaired/not calibrated and the product will be labelled accordingly. Should the product not fulfil the 

warranty, the claim of the buyer and the obligations of ACE Instruments are limited exclusively to the discretion 

of ACE Instruments for exchange, repair of the affected goods or reimbursement of the purchasing price for 

the faulty merchandise.

2. APPLICATION RESTRICTION

ACE  Instruments is  by  no  means  liable  for  additional,  incidental  or  consequential  damage such  as,  among 

others,  lost  profit  and  downtime  that  result  from  selling,  producing  or  using  products  that  are  part  of  this 

application restriction. This is independent of any claims emanating from, for instance, contracts, negligence 

or other culpable actions. 

The  product,  which  is  accompanied  by  this  warranty  and  liability  declaration  (no  matter  the  version  or 

designation), in particular cannot be used in a legally binding manner to determine one’s capability to operate 

vehicles or execute action that could lead to personal injury or injury to others under the influence of alcohol. 

The  thorough  check  for  damage  of  all  products  upon  receipt,  calibration  suitable  for  the  given  use  by the 

buyer and the proper use, maintenance and service according to the instructions of the accompanying ACE 

Instruments  product  literature  are  mandatory  prerequisites  of  this  warranty.  Maintenance  and  service  work 

performed by non-qualified persons as well as the use of non-approved consumables or spare parts results 

in the voiding of this warranty. As for all technically challenging products, it is a fundamental prerequisite and 

mandatory for ACE Instruments warranty that all users of these product are familiar with the properties and 

restrictions of the devices as stated in the respective literature.

3. ADVICE RESTRICTION

The  buyer  is  solely  responsible  and  confirms  that  they  have  checked  the  intended  use  and  suitability 

of  purchased  goods  for  any  purpose.  Between  the  two  parties  it  is  expressly  agreed  that  all  technical  or 

other advice given by ACE  Instruments regarding the use  of goods  or  services is free  of charge and made 

under risk to the buyer exclusively. Therefore, no obligation or liability can result to ACE Instruments from any 

recommendation or their consequences.

Reviews: