Tips to Receive the Most Accurate Results

A)

 Wait at least 15 minutes after your last sip of alcohol. Do not eat, drink, or smoke during that time.

B)

 Do not open the casing.

C)

 Do not keep the breathalyzer in cold, hot, moist, or badly ventilated places.

D)

 Keep the breathalyzer out of the reach of children.

E)

 Conduct three inlet tests after long storage before conducting the actual alcohol test.

F) 

Do not drop the breathalyzer.

G)

 Change the battery if it is depleted. Diminished battery capacity leads to incorrect test results.

H)

 Do not conduct tests in loud (sound waves disrupt the sensor), drafty, or poorly ventilated places.

I)

 After a test result of 1.000 per mill (per mill = EU setting) / 0.100 % BAC (% BAC = US setting) / 0.500 mg/L  

(mg/L = UK setting) or higher the sensor needs rest time. In this case wait at least three minutes before starting 

the next test.

J)

 Do not conduct tests in very cold, very hot, or an unventilated, smoky ambience.

K)

 Store the breathalyzer in a way to avoid penetration by dust or liquids.

L) 

Blowing too hard may cause damage to the sensor as saliva flows into it.

Preparation for the Test

1.

 Push the battery cover (on the back of the device) downwards and open it. Install the 2 AA batteries (delivered 

together with the device) in the battery compartment while taking note of the battery polarity. Close the battery 

cover again.

2.

 Insert a mouthpiece into the slot on the right front side of the breathalyzer. Ensure whether it is securely fitted. 

It is highly recommended to use a new mouthpiece for every test for sanitary reasons.

Conducting the Measurement

1.

 Push the power button on the front of the device, then you hear one beep tone

and shortly will see the number of all tests ever performed with the device – this is only shown as long as you 

keep pressing the power button. If you don`t press it anymore then you see “WAIT” on the right top corner of 

the display, additionally a countdown starts.

2.

 Wait until the end of the countdown, you hear 2 beep tones and you see “blow” on the display.

3. 

As soon as you see “blow” start blowing steadily into the mouthpiece for 4 seconds, the device will beep 

constantly during the test. Tip: Blow like you would whistle without a tone (but without a break).

4. 

As soon as the beep stops and a 2-fold beep is heard, the test is finished. If the breath test was interrupted or 

too weak, „Flo“ appears on the display. In this case, perform the test again and press the start button.

5. 

After a successful breath test, the device evaluates the measurement result. The digit „0“ moves from left to 

right across the display. After a few seconds a beep sounds and the measuring result is shown on the display 

with 4 digits (with  3  decimal  places) in per  mille (=g/L). After  10 seconds you will  hear  several beeps, which 

announces the automatic switch-off of the instrument.

Note:

 For a new test, simply press the start button again. You can also switch off the device manually by pressing 

the start button continuously for approx. 3 seconds, „Out“ appears on the display and the device is switched off.

ACE Instruments Recommends

 

Š

Always use a new mouthpiece for each person and test that is conducted. ACE Instruments assumes no 

liability for any damages that may arise when several people use the same mouthpiece for multiple tests.

 

Š

Only  use  the  provided  individually  packaged  and  hygienic  mouthpieces.  During  each  test  the 

breathalyzer’s  internal  and  external  parts  come  into  contact  with  human  secretion  (saliva,  blood,  

sweat, etc.)!

 

Š

Use  safety  gloves  when  pulling  out  a  mouthpiece  used  by  another  person!  You  can  buy  appropriate 

gloves at ACE Technik (www.ace-technik.de).

IMPORTANT NOTICE

 

Š

WHEN YOU HAVE  EATEN, DRUNK ALCOHOL OR, SMOKED  A  CIGARETTE, WAIT  AT LEAST  15 MINUTES 

BEFORE STARTING THE MEASUREMENT. ANY TEST CONDUCTED PRIOR TO THE EXPIRATION OF  THE 

RECOMMENDED WAITING PERIOD WILL RESULT IN INACCURATE RESULTS.

 

Š

IF THE  TEST RESULT IS  BELOW  0.10‰  (PER MILL =  g/L)  OR 0.01%  BAC (US setting) OR 0.05mg/L  (UK 

settting) THEN THE DEVICE SHOWS 0.00 (‰ OR % BAC OR mg/L – depending on the setting) ON THE 

DISPLAY. THIS HAPPENS BECAUSE AT A LOW RANGE OF ALCOHOL CONCENTRATION IT IS POSSIBLE TO 

MEASURE OTHER MATERIALS IN YOUR MOUTH.

 

Š

This breathalyzer is a high quality and sensitive measurement device. To maintain the accuracy of the 

sensor, it should regularly be used. If the device is not used for an extended period, the sensor can dry 

out. ACE Instruments recommends using the breathalyzer at least 2 times per month (even if you have 

not been drinking alcohol).

 

Š

Due  to changes in the product,  the procedures  stated  can change.  This can take place  without prior 

notice or adaptation of the operating manual and is no cause for complaint, return or price reduction. The 

user is responsible for recognizing discrepancies between the operating manual and the actual handling 

of the breathalyzer and must react accordingly. 

Only Use Original ACE Instruments Mouthpieces

 

Š

Guarantees test result accuracy

 

Š

Guarantees hygiene of you and the device

 

Š

Guarantees full warranty of this device

ACE INSTRUMENTS ADVISES

EVEN  IF  YOU  GET  A  RESULT  MEANING  „SAFE  RANGE“,  YOU  SHOULD  NEVER  DRIVE  AFTER  CONSUMING 

ALCOHOL OR DO ANY OTHER ACTIVITIES THAT ARE SEVERELY IMPAIRED BY ALCOHOL CONSUMPTION AND 

MIGHT ENDANGER YOUR HEALTH AND SAFETY OR THE HEALTH AND SAFETY OF OTHERS.