CARE AND MAINTENANCE
Regular maintenance of the ACE.BOIL water system can help prevent damage or downtime. Service should be performed by
qualified and authorized personnel only.
Warning: Disconnect the power supply from the ACE. BOIL water system before carrying out maintenance on it.
Ÿ
Clean exterior surfaces of the unit with a soft, lint-free cloth. Never use alcohol, paint thinner, benzene or other solvents to clean
the unit. Never use an abrasive material such as a brush or scouring pad to clean surfaces.
Ÿ
Close/open system valve and safety valve every 6 months.
Ÿ
Always test your cleaning solution on an inconspicuous area before applying to the entire surface.
Ÿ
Keep the ACE.BOIL water system in a dry, clean space. Minimize exposure to dust. The power button or other controls should
never be wet.
Ÿ
If the ACE.BOIL water system needs service, please consult the authorized dealer. Unauthorized service may void the warranty.
Ÿ
Wipe surfaces clean after applying cleaner.
Ÿ
Never expose the unit to vibration.
Ÿ
Make sure that all cabin ventilation outlets are always free.
Ÿ
In the event of mechanical/power failure or damage, do not attempt to repair the system unit or wires. Refer all such problems to
an authorized technician.
Ÿ
If the unit gets wet, immediately shut off power. Wait for the unit to completely dry before turning it on again.
Ÿ
Clean aerator once a year.
No water owing, the
water is owing too
slowly.
-Main water supply valve is turned off.
-Safety valve is turned off.
-Turn on the main water supply valve.
-Turn on the safety valve.
Symptom Possible Cause Solution
- No connection between faucet, boiler, lter and
safety valve.
- Connect all the cable and hose correctly.
- Filter is not installed correctly.
- Tighten lter.
- Hoses are kinked.
- Check whether hoses are kinked.
- There is limescale or dirt in the aerator.
- Clean/replace the aerator.
The water is sputtering or
is irregular.
- Check the water pressure. It should be above 1.0 bar. Check a
different tap. If the pressure is also low there, check the mains
water tap and contact your water supplier.
- There is no or too little water pressure.
No boiling water
- The boiler is powered off or not connected to
power supply wall socket(Red LED light is off.).
- Connect to power supply wall socket and press the Power button
on the boiler to power on it.
- The boiler has not yet reached the correct
temperature.
- Check whether the red light is blinking and wait until the red light
is lit up.
- Current limit fuse is burned out and cut off
electric power due to over current.
- Check the fuse and if found to be burned out , contact ACE Water
Systems service to replace fuse with a new one.
- Contact ACE Water Systems service.
- Faulty cables/hoses.
- Contact ACE Water Systems service.
- Faulty safety valve.
- Reset the boiler by pressing the Power button to "Off" position and
back to "On" position after 30 sec.
- Faulty function of boiler.
11
Read and follow assembly instruction. If the ACE.BOIL water system does not functioning properly please check troubleshooting
table. If the water system still not working properly, disconnect it and contact authorized ACE customer service for assistance.
When calling for assistance, please provide your product model and serial number.
TROUBLESHOOTING
!