background image

 

 

4

ACDC Motorized Solutions Pty. Ltd. 

 

RollerGlide

 Rolling Door Operator  

 

 

Installer fitting instructions…. continued 

 

 
Setting obstruction force (see figure 3) 

This facility is provided to stop the door when it encounters an obstruction or jambs. 

For each installation the obstruction force setting must be adjusted.

 

Failure to do 

this correctly may cause serious injury or damage, and will void any warranty.

 

 

Screwdriver adjustments are made on the blue control panel located on the 
control board

 

 

Use the remote control (or optional fixed push button) to operate the door 
when setting these controls 

 

To test the obstruction force, press the remote control (or optional fixed push 
button) to close the door 

 

Obstruct the door by holding it at the bottom, this will cause it to stop and 
reverse 

 

For the obstruction sensing to detect an object in the door way, some force will 
be applied to the object which may suffer damage or injury to the object, 
person and/or door. 

 

Set this for the required force with the close force adjusting control 

 

The open force is set by holding the door when it is opening; this time the door 
will just stop 

 

Periodic maintenance is required to maintain optimum performance. The 
obstruction force may need to be re-adjusted in the future as the door ages.  

 

 

Auto-Close (see figure 3) 

This feature allows the door to close automatically 45 seconds after it opens 

Photo Electric Safety Beams must be fitted to use this feature as a practical 
necessity and to conform to required regulations.

 A safety circuit is provided for 

this purpose see 

photoelectric beam 

section on this page. 

This option is selected by moving the link on plug J1 located at the middle top of the 
control board 
J1 has 3 pins the off position links the centre pin to OFF. The on position links the 
centre position to ON. (Normal factory setting is OFF) 

 
Manual push button (see figure 3) 

If required a normally open push button can be connected to the screw terminals  
CO and BT located at the centre bottom of the control board on terminal block X4 
 

Photoelectric beam (see figure 3) 

 

Use screw te24 and 0V for the detector 24volts power 

 

Remove the link from CO & IR and connect the photoelectric detector switch 
to these terminals. This switch must be closed when operating normally and 
should open when the beam is broken 

 

The screw terminals are located at the bottom on the controller board on 
terminal block X4 