4.6  M2 logistics protective caps 

M2  logistics  protective  caps  are  another  accessory  for  the  M2Smart

®

SE.  Their  purpose  is  to  increase  fall 

protection. M2 logistics protective caps are designed for the upper and lower blind cap. 
 

 

Figure 27: M2 logistics protective caps

 

 
To charge the M2Smart

®

SE in the DS2Smart

®

, the M2 logistics protective caps must be removed.   

 

4.6.1  Security Advices 

 

 

ATTENTION 

Unintended use of the M2Grifp5 should be avoided.

 

 
 

4.6.2  Attaching M2 logistics protective caps to the M2Smart

®

SE 

To  attach  the  upper  and  lower  M2  logistics  protective  cap  to  the  M2Smart

®

SE,  place  it  over  the 

corresponding blind cap. 
 
The upper logistics protective cap is marked by the ACD logo and also has a recess for the scanner. 
 

 

Figure 28:

 

Attaching the upper logistics protective cap 

 
 
The lower logistics protective cap is identified by the recess for the retaining strap and the charging contacts. 
First loosen the retaining strap  and then attach the lower logistics protective cap.  You can then reattach the 
retaining strap. 
 

Summary of Contents for M2Smart SE

Page 1: ...M2Smart SE_Set_Brief Overview_V1 02_en_es_fr 1 32 Brief Overview Resumen breve Aper u rapide Accessories M2Smart SE Accesorios M2Smart SE Accessoires M2Smart SE Version Versi n 1 02...

Page 2: ...is document may not be duplicated or made accessible to third parties without written permission by ACD Todos los derechos reservados Este documento no se puede reproducir ni facilitar a terceros sin...

Page 3: ...serting the Mobil Handheld Computer in and removing it from the docking station 15 4 3 3 Inserting the replacement rechargeable battery in and removing it from the docking station 16 4 3 4 Status LEDs...

Page 4: ...e Original Spare Parts Only There are several accessories for th M2Smart SE available which are explained below M2UHF RFID Shortrange Figure 1 M2UHF RFID Midrange Figure 2 Docking station DS2Smart Cha...

Page 5: ..._en_es_fr 5 32 Figure 3 DS2Smart Charging and transmission box Figure 4 DS2Smart Charging box Figure 5 DS2Smart Developer box Figure 6 DSBattery 2 fold Figure 7 M2Grip5 Figure 8 M2 logistics protectiv...

Page 6: ...F to 140 F Charging temperature 5 C to 35 C 41 F to 95 F The device should only be used in the deep freeze area after the starting process 3 Scope of Delivery The scope of delivery described above can...

Page 7: ...act ACD Elektronik GmbH ATTENTION Before use the contacts of the modules and the contacts of any plugs present must be checked for dirt and cleaned if necessary ATTENTION Unintended use of the interfa...

Page 8: ...emoving the upper plug in module Figure 11 Attaching and removing the lower plug in module When attaching and removing the modules please do not reach into the area of the plug in sliding mechanism as...

Page 9: ...here is a risk of injury due to pinching when sliding The scanner glass can also be soiled in the process ATTENTION The maximum permissible ambient temperatures for the modules are listed below Operat...

Page 10: ...pper plug slide mechanism it can be used for reading UHF RFID tags To do this start a software application to initialize the module Then the read process can be carried out with the software applicati...

Page 11: ...3 formerly 18000 6C DRM Dense Reader Mode support Output power 0 dBm until 23 dBm 4 2 4 FCC Statement of Compliance This device complies with Part 15 of the FCC Rules Operation is subject to the follo...

Page 12: ...is a risk of injury due to pinching when sliding The scanner glass can also be soiled in the process ATTENTION The maximum permissible ambient temperatures for the modules are listed below Operating t...

Page 13: ...per plug slide mechanism it can be used for reading UHF RFID tags To do this start a software application to initialize the module Then the read process can be carried out with the software applicatio...

Page 14: ...eader Mode support Output power EU 0 dBm until 27 dBm Output power USA and Canada 0 dBm until 26 5 dBm 4 2 10 FCC Statement of Compliance This device complies with Part 15 of the FCC Rules Operation i...

Page 15: ...should be checked for damage Damaged parts should be replaced Please contact ACD Elektronik GmbH to do this ATTENTION For indoor use only ATTENTION To prevent overheating the Mobile Handheld Computer...

Page 16: ...3 3 Inserting the replacement rechargeable battery in and removing it from the docking station To insert the replacement rechargeable battery in the device tip it diagonally downward and place it in t...

Page 17: ...ssarily long time 4 3 4 Status LEDs The status LEDs of the DS2Smart docking station will be described below Figure 19 Status LEDs of the DS2Smart Charging cradle for M2Smart SE Speed CHARGE LED lit re...

Page 18: ...docking station Do not use the ACD approved components with a third party device ATTENTION Before use the Mobile Handheld Computer incl battery docking station power supply and any connection cables...

Page 19: ...he replacement rechargeable battery from the docking station first open the lock by pressing toward the surface of the rechargeable battery Remove the rechargeable battery upward Figure 21 Removing re...

Page 20: ...le battery CHARGE LED lit red Replacement battery is being charged CHARGE LED lit green Replacement battery is fully charged CHARGE LED not lit There is no replacement battery inserted in the docking...

Page 21: ...or the M2Smart SE with 2D shortrange scanner SE4770 4 5 1 Security Advices ATTENTION Unintended use of the M2Grifp5 should be avoided 4 5 2 Attaching M2Grip5 to the M2Smart SE To attach the M2Grip5 to...

Page 22: ...he M2Grip5 slide the side sections of the M2Grip5 off the device Then you can guide the M2Grip5 out of the upper retaining strap attachment Figure 25 Removing M2Grip5 from M2Smart SE 1 2 Figure 26 Rem...

Page 23: ...ENTION Unintended use of the M2Grifp5 should be avoided 4 6 2 Attaching M2 logistics protective caps to the M2Smart SE To attach the upper and lower M2 logistics protective cap to the M2Smart SE place...

Page 24: ...logistics protective caps from the M2Smart SE To remove the upper and lower M2 logistics protective caps from the M2Smart SE remove them from the blind caps Figure 30 Removing the upper logistics prot...

Page 25: ...M2Smart SE_Set_Brief Overview_V1 02_en_es_fr 25 32 Figure 31 Removing the lower logistics protective cap...

Page 26: ...approved components with a third party device ATTENTION Before use the Mobile Handheld Computer incl battery docking station power supply and any connection cables should be checked for damage Damage...

Page 27: ...nward and place it in the rechargeable battery compartment Insert the rechargeable battery so that the contacts are aligned with the contacts of the device Then the rechargeable battery can be folded...

Page 28: ...ION All components must be disposed of properly at the end of their technical lifetime Turn off the device before starting any cleaning or maintenance process Make sure that the laser beam is switched...

Page 29: ...you Monday to Thursday from 8 00 am to 5 00 pm CET and Friday from 8 00 am to 3 00 pm CET 7 Service and Spare Parts If you have service requests please contact Hegele Logistic LLC 1001 Mittel Drive IL...

Page 30: ...any within eight 8 days following delivery or installation of the Products with notice of any non conformities or visible defects any warranty claims in this regard shall be deemed waived 1 4 Customer...

Page 31: ...TO DAMAGES FOR LOSS OF PROFITS REVENUE GOODWILL OR USE INCURRED BY CUSTOMER OR ANY THIRD PARTY WHETHER IN AN ACTION IN CONTRACT TORT STRICT LIABILITY OR IMPOSED BY STATUTE OR OTHERWISE EVEN IF ADVISED...

Page 32: ...eil ne doit pas produire de brouillage L appareil doit accepter tout brouillage radio lectrique subi m me si le brouillage est susceptible d en compromettre le fonctionnement 9 1 M2UHF RFID Shortrange...

Reviews: