The heater(s), contactor(s), and all controls are located under the control console located on the right-hand side of 

the kettle.  These components are accessible with the control console panel removed. 

No special tools are required for removal or replacement of malfunctioning components. 

Most electrical component failure can be easily diagnosed by following a logical process of elimination. 

The thermostat, and primary coil on the transformer (380, 415,440,480v only) can be tested for continuity.  An open 

circuit indicates that the component has failed. 

It is necessary to disconnect the heater wires from the contactor(s) before testing the heating element(s) for 

continuity. 

The coils on the low water control relay, contactor(s), secondary coil of the transformer (380 & 480v only), and the 

thermostat indicator light can also be tested for continuity; however, it will be necessary to disconnect these 

components from the circuit before testing. 

Also check the transformer (380, 415,440,480v only) for coil to coil shorting if any control circuit components have 

failed.  Reference appropriate schematic diagram for model to be serviced. 

Heating element failure may be attributed to chattering of the contactor(s) or the low water control relay, cause by 

burned or pitted points.  Be sure to check for burned or pitted points in the contactor(s), if element(s) need 

replacing.

 

Re-Calibrating Thermostats 

If the thermostat is defective or not working properly, it must be replaced (without breaking the seal) 

and returned to 

Accutemp

.  The warranty is voided if the seal is broken or an attempt is made to 

recalibrate the thermostat.

  

See below for replacement instructions of the thermostat.  

Primary Thermostat Replacment 

Disconnect power and remove service panel.  

Disconnect and mark wire(s) connected to the normally closed position with the enclosed tag marked normally 

closed.  

Disconnect and mark wire(s) connected to the common position with the enclosed tags marked common.  

Drain water in jacket below the thermobulb location. 

Remove the 3/8” hex pipe plug, which holds the thermobulb in place in the weld coupling.  Pull thermobulb and 

capillary tube out of the kettle jacket.   

Remove the two mounting screws on the existing thermostat from the front panel. 

Use the existing hole locations for mounting the thermostat.  The two outer holes on the new thermostat bracket 

are for mounting the thermostat and the two inner holes are for mounting the bezel.  With a marker, mark the 

hole locations for drilling the bezel holes.   

Drill holes through the front panel with a #32 drill bit 

Locate the new replacement thermostat on the inside of the control box where the existing thermostat was 

mounted.  The thermostat should be mounted with the flat side of the dial stem facing the right side of the unit 

and the common pole (“P” terminal) will be on the left side.  You will use the #6-32x1/4” round head slotted 

screws provided to mount the thermostat in the two outer holes. 

10  After this has been completed, Secure the bezel in place with the #6 Type “F” x 5/16” pan head phillips thread 

cutter screws provided in the two inner holes which should have been drilled out in step 7.  Note:  The triangular 

indicator marking on the bezel should be in the 3 o’clock position. 

11  Reconnect the wires marked normally closed to the normally closed position on the new replacement 

thermostat with the piggyback push-on connector (if more than one connection is needed) or a single push-on 

connector (if only one connection is needed) as provided in the installation package. 

12  Carefully uncoil the capillary tube. Re-insert thermobulb and 2 inches of the capillary tube through the weld 

coupling from which the old tube and bulb were removed.  

Caution:  Do not make any threaded connections 

5

Summary of Contents for EDGE ALTEH-5

Page 1: ...Made in U S A INSULATED SELF CONTAINED TILTING TABLE TOP ELECTRIC OWNERS MANUAL AND INSTALLATION INSTRUCTIONS Models ALTEH 5 and ALTEH 10 MODEL ALTEH 10...

Page 2: ...Calibrating Thermostats 5 Primary Thermostat Replacement 5 Heating Element Replacment 6 Trouble Shooting 6 Illustrations 7 Caring for Stainless 8 Sanitizing 8 Parts List 10 Wiring Diagrams 11 11 12 20...

Page 3: ...for safe delivery to the customer until customer acceptance of the package Careful inspection of the packaging and the appliance should be completed before acceptance from the transportation company...

Page 4: ...n the main and the kettle All electrical connections must be in accordance with all applicable electrical codes The electrical wiring diagram is located inside the control housing Caution Kettle must...

Page 5: ...is particularly true if the unit is cold Keeping the cover closed during this heat up time will speed up the process If a new temperature is desired during the cooking operation turn the control therm...

Page 6: ...E Caution Be sure the main power supply switch is OFF before cleaning and or servicing Caution Use of any replacement parts other than those supplied or authorized by manufacturer voids all warranties...

Page 7: ...ected to the normally closed position with the enclosed tag marked normally closed 3 Disconnect and mark wire s connected to the common position with the enclosed tags marked common 4 Drain water in j...

Page 8: ...ng Install new element in coupling and reconnect wires to the contactor Make sure all covers are replaced after all repairs are completed Trouble Shooting The TT TT2 3J T E20QT and TT TT2 3J T E40QT k...

Page 9: ...to see if it is too low Contactor for dirt or corrosion on the contacts Uneven cooking due to cold spots For burned out open or loose heating elements See Service section for test and replacement pro...

Page 10: ...agents thoroughly with water wipe dry and then allow the surface to air dry Oxygen actually helps maintain stainless steel s protective surface Never use cleaners containing chlorides or quaternary s...

Page 11: ...valent to one that supplies 200 parts per million available chlorine Obtain advise on sanitizing agents from your supplier of sanitizing products Following the supplier s instructions apply the agent...

Page 12: ...408015 25 Contactor 25 amp 600V 2 408015 40 Contactor 40 amp 600V 2 408015 60 Contactor 60 amp 600V 2 430033 Transformer all volts 480 440 415 380 1 400749 1 Ground lug 14 to 6 2 406619 Fuse 2 amp 2...

Page 13: ...Wiring Diagrams ALTEH 5 10 GAL 208 240 3PH 11...

Page 14: ...Wiring Diagrams ALTEH 5 10 GAL 440 460 480 3PH 12...

Page 15: ...Wiring Diagrams ALTEH 5 10 GAL 380 415V 3PH 13...

Page 16: ...Maintenance Service Log Model No Purchased From Serial No Date Purchased Purchase Order No Location Installed Date Installed Date Maintenance Performed Performed By 14...

Page 17: ...rm the repair or replacement This warranty includes travel time not to exceed two hours and mileage not to exceed 50 miles 100 miles round trip but does not include post start up assistance or trainin...

Page 18: ...IMPORTANT SERVICE INFORMATION AccuTemp Product Inc Technical Customer Support Technician is available Monday thru Sunday 7 00am to 7 00pm EST...

Reviews: