Safety Cautionary Information 

Before using your new Accuro Handrail Scale, please take time to read the following safety 
instructions.  

CAUTION!

  Properly assemble scale and follow all directions in the user manual.  

CAUTION!

  Place scale only on a level, stable surface to reduce the chance of patient tipping. 

CAUTION!

  To ensure stability, it is recommended to use the scale on a hard surface only.  If 

the floor is carpeted, ensure the carpeting is a low pile so the bottom of the scale clears the top 
of the carpet pile. 

CAUTION!

  Always keep a clear pathway around the scale, to prevent user injury. 

 

Important Information 

• Do not drop the scale.  

• Use only the type of battery stated. 

• Do NOT press the scale display buttons with sharp objects (pens, instruments, etc.), as 
damage to the product for this reason is not covered under the warranty. 

• Have scale serviced and re-calibrated on a regular basis. 

• Have repairs carried out only by authorized persons. 

Warranty 

 

This scale features a one-year limited warranty from date of delivery. Warranty applies to 
defects attributed to poor materials or workmanship. All moveable parts including batteries and 
cables are excluded. In the event of transport damage, claims under warranty can be honored 
only if the complete original packaging is used for any transport and the scale is securely 
repackaged. Warranty is limited to the repair or replacement of the defective product and in no 
event shall Accuro be liable for consequential or indirect damages to equipment or personnel.  

 

Before you start 

Carefully remove the scale from the shipping carton.  If you notice any shipping damage to the 
product, please contact the shipper immediately.  Please retain all shipping material in case the 
product needs to be returned or the scale needs to be shipped to another location. 

Remove the packaging and place the scale on a firm, level surface. Contents include:  

  Weighing platform 

  Column with Indicator 

  Left and Right Handles 

  AC Adaptor 

 

 

 

 

Summary of Contents for HRS305

Page 1: ...HRS305 Hand Rail Scale ...

Page 2: ...ar basis Have repairs carried out only by authorized persons Warranty This scale features a one year limited warranty from date of delivery Warranty applies to defects attributed to poor materials or workmanship All moveable parts including batteries and cables are excluded In the event of transport damage claims under warranty can be honored only if the complete original packaging is used for any...

Page 3: ... scale on a carpeted surface please ensure that the bottom of the scale platform does not touch the carpet Assembling the scale 1 Your scale will arrive unassembled as shown below 2 Place the base of the scale on a solid surface or the floor as shown 3 Locate the connector at the bottom end of the column and connect the connector receptacle in the base as shown below before assembling the main col...

Page 4: ...lumn to the base as shown below and fully tighten the two thumb screws that are permanently attached to the back of the base 5 Attach the handles to the main collumn by inserting the bottom of the handle first into the base ...

Page 5: ...handle bracket to line up with the column and insert two screws on each side and one in the back as shown below Make sure to tighten screws to safely secure the handles to the column 7 Your scale is now fully assembled and ready to use ...

Page 6: ...to remove the user from the scale platform Stabilizing Feet Self leveling feet that automatically adjust to floor surfaces and stabilize the scale platform NOTE Do NOT press the scale display buttons with sharp objects pens instruments etc Scale Operation User weighing 1 Step on the scale and remain still 2 When a stable weight is reached the display will beep and hold the weight reading 3 The sca...

Page 7: ...e becomes stable REWEIGH Button 1 Use the REWEIGH button to reinitiate a patient weighing without having to remove the patient from the scale platform Power Supply The scale is generally powered by the supplied AC Adaptor 4 AA batteries can be used as a power back up and will supply enough power to power the scale for 7 days Carefully lower scale to flat position on floor so that the bottom of the...

Page 8: ... o Check the batteries o Check that AC adaptor is plugged into unit and outside power source 0 0 does not appear before the weighing operation o Press the ZERO button to turn on the scale there must not be any load on the scale appears instead of 0 0 before weighing o Press the ZERO button there must not be any load on the scale one display window is illuminated constantly or not at all o The rele...

Page 9: ...ied service agent is used For further information or assistance please contact us at support accuroweigh com Technical Data Dimensions Width 23 5 Height 46 Depth 28 Platform Size 28 x 23 5 x 2 75 Weight 38 lbs Power supply AC Transformer 120v AC 60 HZ 100mA 9v DC 400 Ma Batteries 4 AA size LCD 1 LCD text character w orange back light Capacity 1000lb x 0 1 lb 453 kg x 0 05 kg Accuracy 0 1 lb 0 05 k...