Accurex DSX Series User Manual Download Page 7

 

 

 

(1) 

Put enough samples on the scale, press

TARE

key to complete the sampling. 

 
(2) By pressing the

UNIT

key, the ‘WEIGHT’ window displays ‘000000’,press 

 

key to adjust 

the number of weights, press

TARE

  key to confirm. 

 
When the weight of the sample is less than 0.1% of the maximum capacity of the scale, the ‘WEIGHT’ 
window displays ‘-CSL-’, which means the sample is insufficient and needs to be sampled again. 
Press 

SETUP

key to re-sample, press

MODE

  key to return to the weighing mode. 

 
When  percentage  sampling  is  complete,  the  ‘WEIGHT’  window  displays  the  current  weight  as  a 
percentage of the sample weight, accurate to 0.1%. 
 
Under sampling mode, press

SETUP

key to exit sampling mode. 

 
 

4.  [Set Alarm]

 

 

Under the weighing mode or counting mode, long press

UNIT

key, the ‘WEIGHT’ window displays 

‘HL---ZL’. Press

key to switch between ‘HL---ZL’ and ‘HL---PCS’. ‘HL---ZL’ stands for set weight 

alarm, while ‘HL---PCS’ stands for set quantity alarm, and press

TARE

key to confirm. 

 
The ‘WEIGHT’ window display with the last set alarm upper limit and the prompt ‘-HH-’ in turn, if you 
do not need to change the previous set value, press 

TARE

  key to directly enter the next step to 

set the alarm lower limit; if you need to change the previous set value, press

key to input the 

number, press 

TARE

key to confirm current value, and began to set the next, if it is the most at 

the end of the value, then automatically enter the next step to set the alarm lower limit. 
 
If you just enter the state of setting alarm lower limit, the ‘WEIGHT’ window displays the last set 
weight lower limit and prompt ‘-LL-’ in turn. The operation of this process is the same as setting alarm 
upper limit. After the setting of alarm lower limit, enter the setting of alarm mode. 
 
When setting the alarm mode, the ‘WEIGHT’ window displays ‘-IN-’ stands for set alarm within this 
range, ‘-OUT-’ stands for set alarm without this range, and ‘-NO-’ stands for no alarm. At this time, 
press 

key to switch and press

TARE

key to confirm. 

 
During the setting alarm process, press

SETUP

key to exit the setting, and the current setting 

value is invalid. 

 
 

5.  [Weight Calibration]

 

 

After starting up the scales, long press 

SETUP

key to enter the calibration. 

 
The ‘WEIGHT’ window displays ‘D-----5’, press 

key to adjust the division value within’1/2/5/10/20’, 

and press 

TARE

  key to confirm.   

Summary of Contents for DSX Series

Page 1: ...User Manual DSX series Scale EN ...

Page 2: ......

Page 3: ...ject under the weighing plate 4 Power must be cut off before cleaning and maintenance 5 Please weigh within the specified range when weighing 6 Shall not be used in bad environment 7 When taking the electronic scale do not force on the bracket or weighing plate 8 The maintenance of electronic scale must be maintained by authorized professional personnel 2 Packing list 1 2 3 4 5 Electronic scale Sc...

Page 4: ... from other electrical appliances The first use should be charged for more than 12 hours 3 When the power is on please do not put anything on the scale plate Maximum capacity g 3000 6000 15000 30000 Minimum capacity g 20 40 100 200 verification scale intervale g 1 2 5 10 Division g 0 1 0 2 0 5 1 Minimum sample weight g 2 4 10 20 Minimum single weight g 0 15 0 3 0 75 1 5 Minimum sampling quantity P...

Page 5: ...t to zero 2 UNIT key Weighing unit select you can choose KG G or LB as your weighing unit if you received the scale maximum capacity 15kg the unit will be as G if you received the scale maximum capacity 30kg the unit will be as KG in weighing counting mode the key is used to set upper and lower alarm range 3 TARE key In the normal state to clear the tare of the item In counting percentage set alar...

Page 6: ...ow The weight could displays 0 by pressing ZERO key Zeroing range 4 FS For example a 300 kg scale can only be tared 12 kg weight This function is not available in the TARE mode 2 Counting Mode Under counting mode press MODE key to enter percentage mode In counting mode press SETUP key to start weight sampling the WEIGHT window displays SAPX X is the number of samples Press key screen will display ...

Page 7: ...u do not need to change the previous set value press TARE key to directly enter the next step to set the alarm lower limit if you need to change the previous set value press key to input the number press TARE key to confirm current value and began to set the next if it is the most at the end of the value then automatically enter the next step to set the alarm lower limit If you just enter the stat...

Page 8: ... 9 Points for attention 1 THE SECURITY The user must use the right way to access and use the power supply check whether the connection is in good condition You must unplug the power cord before replacing the fuse 2 MAINTENANCE 1 Gently move the scale to avoid falling or collision 2 Clean the scale with a dry or wet cloth When the water into the scale do not clean to avoid damage Do not use organic...

Page 9: ...omparison It is better to compare with the electronic scale before use every day If there is any doubt about the scale it should be stopped immediately and sent to the metrological testing institution or the authorized maintenance center for inspection 6 When using the scale if Lb is displayed in the WEIGHT window it means that the scale battery can only be used for a short time and it is time to ...

Page 10: ...01 16062021 ...

Reviews: