Manual Part # 800-1405-001, Rev A
Page 16 of 20
Circuit Board Jumpers
JP1
FACTORY USE ONLY
JP2
FACTORY CONFIGURED: DO NOT CHANGE
JP3
Programming Lock-out
Default = Position A
Front panel programming of the Digital Readout can be enabled or disabled
though the use of this circuit board jumper.
Front panel Programming is enabled when the shorting jumper is installed in
position A. To disable Programming, install jumper on position B.
When programming is disabled, user cannot access the programming
functions via the
front panel as described in:
PROGRAMMING PARAMETERS
.
This
provides a method of configuring the Digital Readout with specific
parameters then preventing unauthorized or accidental configuration
changes.
JP4
FACTORY CONFIGURED: DO NOT CHANGE
JP5
FACTORY CONFIGURED: DO NOT CHANGE
DRO Circuit Board
JP3
JP4
JP2
JP5