Deviation from Gain Setting Indicated by Front-Panel Switches: 

+0.25dB maximum, re 1000Hz 

Maximum Recommended Output Level: 

+7dBm 

Total Harmonic Distortion: 

 

 

 

 

 

 less than 1% at +7dBm output level 

Equalized Gain: 

0 to 7.75dB differential between 1000 and 3000Hz  

levels, switch-selectable in 0.25dB increments 

Frequency Response Deviation: 

+1.0dB, re 1000Hz, 300 to 3000Hz 

Delay Distortion:  less than 125

s, 300 to 3000Hz, re 1000Hz 

(measured worst-case with equalization) 

Crosstalk Loss (Between Channels):  

85dB minimum, re 1000Hz 

75dB minimum, re 3000Hz 

Noise:   

15dBrnC maximum at maximum gain 

Crosstalk Loss (between units in adjacent, above, or below shelf slots): 

90dB minimum, re 1000Hz 

85dB minimum, re 3000Hz 

Simplex (SX) Current: 

120mA, maximum, with 5mA maximum unbalance 

Tone Loopback Threshold: 

-18dBm with no gain (Receive channel gain or loss 

adjustments will directly increase or decrease the 

minimum loopback sensitivity on a dB-for-dB basis.) 

Tone Loopback Signal-To-Guard Ratio: 

3dB minimum 

Tone Loopback Frequency: 

1 of 11 prescription set, center stabi0.2%, 

75Hz bandwidth (see table 3) 

Operating Times, Tone Loopback: 

initiate:  1.4 seconds maximum, 

loopback after removal of tone 

release:  0.7 second maximum, 

release during tone (two-tone-burst operation) 

Local DC Loopback: 

ground  to operate; 25mA  current 

Loopback Levels:    +16dB, +9dB, -16dB or-23dB (+1dB), switchable 

Input Power: 

-22 to-56Vdc, 65mA maximum, 25mA quiescent 

6.02   Environmental 

Operating Environment: 

20

 to 130

F (-7 to 54

C)

 

Humidity:  

 

 

to 95% (no condensation)

 

6.03  Physical 

Dimensions: 

 

5.58” H x 1.42” W x 5.96” D

 

(14.17cmH x 3.61cmW x 15.14cmD)

 

Weight:   

 

16 ounces (454 grams) 

 

Mounting: 

 

relay rack or apparatus case via one 

 

position of an Accurate Type-10 

Mounting Shelf 

7.  TESTING AND TROUBLESHOOTING 

7.01

  The  Testing  Guide  Checklist  (Table  5.)  may  be  used  to  assist  in  the 

installation,  testing  or  troubleshooting  of  the  104003C  Prescription  Line 

Amplifier.  The checklist is intended as an aid in the localization of trouble 
to a specific module.  If a module is suspected of being defective, a new one 
should be substituted and the test conducted again.  If the substitute module 
operates  correctly,  the  original  module  should  be  considered  defective  and 
returned to Accurate for repair or replacement as directed below.  We strongly 
recommend that no internal (component-level) testing or repairs be attempted 
on  the  module.    Unauthorized  testing  or  repairs  may  void  the  module’s 
warranty.    Also,  if  the  module  is  part  of  a  registered  system,  unauthorized 
repairs  will  result  in  noncompliance  with  Part  68  of  the  FCC  Rules  and 
Regulations. 

TECHNICAL ASSISTANCE 

7.02

  Contact Accurate Electronics, Inc. 503.641.0118, FAX: 503.646.3903; 

Mail: PO Box  1654, Beaverton OR 97075-1654. 

RETURN PROCEDURE (FOR REPAIR) 

7.03

  To return equipment for repair, first contact Accurate Electronics, Inc.  

Enclose  an  explanation  of  the  malfunction,  your  company’s  name  and 
address,  the  name  of  a  person  to  contact  for  further  information,  and  the 
purchase order number for the transaction.  Accurate Electronics will inspect, 
repair,  and  retest  the  equipment  so  that  it  meets  its  original  performance 
specifications and then ship the equipment back to you.  If the equipment is 
in warranty, no invoice will be issued.   

8.  MAINTENANCE 

8.01

 No preventive maintenance is required. General care is recommended. 

9.  WARRANTY 

9.01

    All  Accurate  Electronics  Inc.  products  carry  a  full  FIVE  (5)  YEAR 

warranty  on  materials  and  workmanship.  See  WARRANTY  in  front  of 
catalog. 

Note:    Warranty  service  does  not  include  removal  of  permanent  customer 
markings on the front panels of Accurate Electronics’ modules, although an 
attempt  will  be  made  to  do  so.    If  a  module  must  be  marked  defective,  we 
recommend  that  it  be  done  on  a  piece  of  tape  or  on  a  removable  stick-on 
label. 

9.02

  If a situation arises that is not covered in the checklist, contact Accurate 

Customer Service as follows (telephone number are given below): 

Contact Accurate Electronic Customer Service 

9.03

 If a module is diagnosed a defective, follow the replacement procedure 

in paragraph 9.04 when a critical service outage exists (e.g., when a system 
of a critical circuit is down and no spares are available).  If the situation is not 
critical, follow the repair and return procedure in paragraph 9.05. 

Replacement 

9.04

  To obtain a replacement module, notify Accurate Electronics.  Be sure 

to provide all relevant information, including the 104003C part number that 
indicates  the  issue  of  the  module  in  question.    Upon  notification,  we  shall 
ship a replacement module to you.  If the module in question is in warranty, 
the replacement will be shipped at no charge.  Pack the defective module in 
the  replacement  module’s  carton,  sign  the  packing  slip  included  with  the 
replacement,  and  enclose  it  with  the  defective  module  (this  is  your  return 
authorization).  Affix the preaddressed label provided with the replacement 
module to the carton being returned, and ship the module prepaid to Accurate 
Electronics. 

Repair and Return 

9.05

  Return the defective module, shipment prepaid, to Accurate Electronics 

Inc. : 

ACCURATE ELECTRONICS INC. 

ATTN: REPAIR AND RETURN 

8687 SW HALL BLVD. #100 

BEAVERTON, OREGON 97008 USA 

 

Summary of Contents for 104003C

Page 1: ...DX loopback and other signaling schemes that require a dc path 1 05 The 104003C provides loopback toward the facility for remote testing of the circuit Loopback may be tone or dc activated In the tone...

Page 2: ...3C are center tapped to derive simplex leads allowing this module to be applied to circuits employing DX loopback or other dc signaling schemes Figure 4 LOOPBACK 2 07 The loopback feature of the 10400...

Page 3: ...described in paragraphs 3 6 through 3 10 Locations of these switches on the module s front panel and printed circuit boards are shown in Figure 5 CHANNEL OPTIONING 3 06 Levels The front panel Gain Los...

Page 4: ...ck Levels Switch Positions S4 1 S4 2 16dB Off Off 9dB Off On 16dB On Off 23dB On On ALIGNMENT 3 11 This alignment subsection is divided into two parts preliminary alignment and final alignment verific...

Page 5: ...the difference in dB between the equalized receive input level or the specified receive input level if equalization was not used and the specified receive output level to determine how much gain or lo...

Page 6: ...tone at the specified level Request that personnel at the distant facility side receive location measure and record the 1000Hz level D Determine the difference in dB between the distant facility side...

Page 7: ...d to Accurate for repair or replacement as directed below We strongly recommend that no internal component level testing or repairs be attempted on the module Unauthorized testing or repairs may void...

Page 8: ...output level paragraph 3 20 4 Disconnect the TMS Connect the properly terminated TMS receive to the TX IN MON jack and insert an opening plug into the TX IN jack Request that personnel at the distant...

Page 9: ...0Hz and 3000Hz signal levels Divide this difference by 2 and referring to table 2 set front panel RX EQL switch for the required nearest but lower amount of equalized gain Nonloaded cable Determine th...

Page 10: ...tches S2 and S4 properly set Level Equalizer switches front panel RX LEVEL and RX EQL properly set Replace module and re test Transmit Level Connect properly terminated TMS receive to TX OUT jack Inse...

Reviews: