ACCURATE ELECTRONICS 104003C Manual Download Page 3

 

ACCURATE ELECTRONICS INC

                               

Practice Section 104003C  Rev A    January 2014

 

 

WWW.ACCURATE.ORG

    PO BOX 1654  97075-1654    8687  SW HALL BLVD  97008      BEAVERTON OR  USA    503.641.0118     FAX 503.646.3903 

 

This document contains proprietary information and is supplied for identification, maintenance, engineering evaluation or inspection purposes only and shall not be duplicated or disclosed without written 
permission of:  ACCURATE ELECTRONICS INC By accepting this document the recipient agrees to make every effort to prevent unauthorized use of this information. 

 

MOUNTING 

3.02

  The 104003C module mounts in one position of a Type-10 Mounting 

Shelf, which is available in configurations for both relay rack and apparatus 
case installation.  The module plugs physically and electrically into a 56-pin 
connector at the rear of the Type-10 Shelf. 

INSTALLER CONNECTIONS 

3.03

  Before making any connections to the mounting shelf, make sure that 

power is 

off 

and modules are 

removed

.  Modules should be put into place 

only 

after

 they are properly optioned and 

after

 wiring is completed. 

3.04

    Table  1  lists  external  connections  to  the  104003C  module.    All 

connections are made via wire wrapping to the 56-pin connector at the rear 
of the module’s mounting shelf position.  Pin numbers are found on the body 
of the connector. 

 

Table 1.

  Installer Connections to 104003C 

CONNECT 

TO PIN 

XMT TIP OUT 

41 

XMT OUT RING 

47 

XMT SIMPLEX OUT 

43 and 45 

RCV TIP IN 

RCV RING IN 

13 

RCV SIMPLEX IN 

9 and 11 

XMT TIP IN 

55 

XMT RING IN 

49 

XMT SIMPLEX IN 

51 and 53 

RCV TIP OUT 

RCV RING OUT 

15 

RCV SIMPLEX OUT 

LOCAL LOOP (Key controlled loopback) 

TEK5 (data set disable lead) 

19 

TEK6 (data set disable lead) 

21 

BATT (-22 to –56Vdc battery in) 

35 

GND (ground) 

17 

DSA POWER (used in 263 Data Station 
Assembly packages) 

 

37 

Note: 

In intermediate applications where simplex (SX) signaling is used 

(see center 104003C in Figure 4), strap the simplex leads as follows:  RCV 
SIMPLEX IN (pin 9) to RCV SIMPLEX OUT (pin 3) and XMT SIMPLEX IN 
(pin 51) to XMT SIMPLEX OUT (pin 43).

 

 

OPTION SELECTION 

3.05

  Option switches must be set before the 104003C is placed into service.  

These switches and their functions are described in paragraphs 3.6 through 
3.10.  Locations of these switches on the module’s front panel and printed 
circuit boards are shown in Figure 5. 

CHANNEL OPTIONING 

3.06  Levels.

  The front panel Gain/Loss slide switches for the transmit and 

receive channels conditions the corresponding channel amplifier to provide 
either gain or loss.  If gain is required, set the switch to the 

GAIN

 position.  If 

loss is required, set the switch to the 

LOSS

 position.  The precise amount of 

gain or loss is selected via the front-panel transmit level and receive level DIP 
switches.    The  amount  of  gain  or  loss  provided  by  each  switch  position 
appears on the front panel of the module adjacent to each switch position (see 
Figure 5).  These values are additive; thus, the amount of gain or loss selected 
is the sum of those switch positions set to 

IN

EQUALIZATION

 

3.07  

  Two five-position DIP switches located on the front panel introduce 

from 0 to 7.75dB of slope equalization in 0.25dB increments in both transmit 
and receive channels.  The various settings of both equalizers are shown in 
Table 2. 

 

Table 2.

  Transmit and Receive channel equalized gain optioning. 

Switch 

positions 

0.25

 

 

0.5 

 

1.0 

 

2.0 

 

4.0 

1000Hz* 

gain 
(dB) 

Off 

Off 

Off 

Off 

Off 

On 

Off 

Off 

Off 

Off 

0.25db 

Off 

On 

Off 

Off 

Off 

0.5dB 

On 

On 

Off 

Off 

Off 

0.75dB 

Off 

Off 

On 

Off 

Off 

1.0dB 

On 

Off 

On 

Off 

Off 

1.25dB 

Off 

On 

On 

Off 

Off 

1.5dB 

On 

On 

On 

Off 

Off 

1.75dB 

Off 

Off 

Off 

On 

Off 

2.0dB 

On 

Off 

Off 

On 

Off 

2.25dB 

Off 

On 

Off 

On 

Off 

2.5dB 

On 

On 

Off 

On 

Off 

2.75dB 

Off 

Off 

On 

On 

Off 

3.00dB 

On 

Off 

On 

On 

Off 

3.25dB 

Off 

On 

On 

On 

Off 

3.5dB 

On 

On 

On 

On 

Off 

3.75dB 

Off 

Off 

Off 

Off 

On 

4.00dB 

On 

Off 

Off 

Off 

On 

4.25dB 

Off 

On 

Off 

Off 

On 

4.50dB 

On 

On 

Off 

Off 

On 

4.75dB 

Off 

Off 

On 

Off 

On 

5.00dB 

On 

Off 

On 

Off 

On 

5.25dB 

Off 

On 

On 

Off 

On 

5.5dB 

On 

On 

On 

Off 

On 

5.75db 

Off 

Off 

Off 

On 

On 

6.0dB 

On 

Off 

Off 

On 

On 

6.25dB 

Off 

On 

Off 

On 

On 

6.50dB 

On 

On 

Off 

On 

On 

6.75dB 

Off 

Off 

On 

On 

On 

7.0dB 

On 

Off 

On 

On 

On 

7.25dB 

Off 

On 

On 

On 

On 

7.50dB 

On 

On 

On 

On 

On 

7.75dB 

*3000Hz equalized gain is twice 1000Hz level shown. 

 

IMPEDANCE MATCHING

 

3.08   

Two  slide  switches  located  on  the  main  pcb  select  the  input/output 

impedances of the facility port (receive in/transmit out – S2) and the terminal 
port (transmit in/receive out – S4).  Each port may be set to impedances of 
150  ohms,  600  ohms  or  1200  ohms.    See  Figure  5  for  location  of  these 
switches. 

Summary of Contents for 104003C

Page 1: ...DX loopback and other signaling schemes that require a dc path 1 05 The 104003C provides loopback toward the facility for remote testing of the circuit Loopback may be tone or dc activated In the tone...

Page 2: ...3C are center tapped to derive simplex leads allowing this module to be applied to circuits employing DX loopback or other dc signaling schemes Figure 4 LOOPBACK 2 07 The loopback feature of the 10400...

Page 3: ...described in paragraphs 3 6 through 3 10 Locations of these switches on the module s front panel and printed circuit boards are shown in Figure 5 CHANNEL OPTIONING 3 06 Levels The front panel Gain Los...

Page 4: ...ck Levels Switch Positions S4 1 S4 2 16dB Off Off 9dB Off On 16dB On Off 23dB On On ALIGNMENT 3 11 This alignment subsection is divided into two parts preliminary alignment and final alignment verific...

Page 5: ...the difference in dB between the equalized receive input level or the specified receive input level if equalization was not used and the specified receive output level to determine how much gain or lo...

Page 6: ...tone at the specified level Request that personnel at the distant facility side receive location measure and record the 1000Hz level D Determine the difference in dB between the distant facility side...

Page 7: ...d to Accurate for repair or replacement as directed below We strongly recommend that no internal component level testing or repairs be attempted on the module Unauthorized testing or repairs may void...

Page 8: ...output level paragraph 3 20 4 Disconnect the TMS Connect the properly terminated TMS receive to the TX IN MON jack and insert an opening plug into the TX IN jack Request that personnel at the distant...

Page 9: ...0Hz and 3000Hz signal levels Divide this difference by 2 and referring to table 2 set front panel RX EQL switch for the required nearest but lower amount of equalized gain Nonloaded cable Determine th...

Page 10: ...tches S2 and S4 properly set Level Equalizer switches front panel RX LEVEL and RX EQL properly set Replace module and re test Transmit Level Connect properly terminated TMS receive to TX OUT jack Inse...

Reviews: