OSD Menus 

User Level 

Field –

 Use the numeric [0-9] buttons followed by the Enter button to enter a luma integer value from 0-

109% for the User Field in the Gray Field group. To restore the original 100% User Field select Factory 
and press Enter. Select “Cancel” and press Enter to leave the menu without making any change. 

Window

 – Use the numeric [0-9] buttons followed by the Enter button to enter a luma integer value from 

0-109% for the User Window in the Gray Scale group. To restore the original 100% User Window select 
Factory and press Enter. Select “Cancel” and press Enter to leave the menu without making any 
change. 

Checkerboard

 – Use the numeric [0-9] buttons followed by the Enter button to enter a luma integer 

value from 0-109% for the User Checkerboard and User Inverse Checkerboard in the Special group. To 
restore the original 50% Checkerboard luma value select Factory and press Enter. Select “Cancel” and 
press Enter to leave the menu without making any change. 

Color

 – Use the Up and Down cursor buttons to select the R, G, or B entry field. Use the numeric [0-9] 

buttons to enter R, G, or B integer values from 0-109%. Press the Enter button to enter the R, G, B 
values as the new color of the User Window and User Field in the Color 75 and Color 100 groups 
respectively. The “White” bars in the color bar patterns are also changed to allow comparison with other 
known colors. To restore the original 75% gray and 100% white colors select Factory and press Enter. 
Select “Cancel” to leave the menu without making any change. 

Note: After you Enter the value changing process you can only exit that process by completing a value 
entry, by highlighting Factory and pressing Enter to reset the value(s), or by highlighting Cancel and 
pressing Enter. After you Cancel or Enter a new value, a “Change” option is highlighted in the menu. 
Press Enter to repeat the User value entry process, or press the left cursor button to move to another 
menu item. 

Note: As you enter digits the digits shift to the left. Press zeros to clear a mis-typed number without 
using Cancel to exit the menu.

 

 

Output 

CVBS/YC

 – Select 0 IRE or 7.5 IRE black level setup for NTSC (480i) CVBS or Y/C signals. 

Channels

 – Enable/disable any combination of RGB or YCbCr (YPbPr) output signals. 

CVBS C BW

 – Select the CVBS (composite video) chroma signal bandwidth. 

YC C BW

 – Select the Y/C (S-video) chroma signal bandwidth. 

Color Matrix

 – Select standard YCbCr/YPbPr HD/SD Rec. 709/Rec. 601 color-matrix encoding, or 

reverse the encoding (HD/SD Rec. 601/Rec. 709). 

HD V Rate

 – Select 59.94 or 60.00 Hz HD signals. 

Summary of Contents for HDG-4

Page 1: ...AccuPel HDG 4000 Documentation HDG 4 User Manual HDG 4 IR Remote Control...

Page 2: ...HDG 4000 ANALOG DIGITAL VIDEO CALIBRATION GENERATOR HDG 4 USER MANUAL 2 AccuPel HDG 4 IR Remote Control for the AccuPel HDG 4000 Analog Digital Video Calibration Generator USER MANUAL Version 0 91...

Page 3: ...SELECTION 6 Color75 Color100 Special PLUGE Gray Scale Gray Field Groups 6 Group 6 Pattern 6 Pat 6 USER DEFINED PATTERN LIST 7 Store Pattern 7 Delete Pattern 7 List 7 List 7 PAT TABLE 7 OTHER FUNCTION...

Page 4: ...with standard digital video levels digital level 16 for black and digital level 235 for 100 reference white RGBs PC selects RGB analog signals with 7 5 IRE setup and RGB digital signals with PC digit...

Page 5: ...signals ALT 24psf Selects 1080p23 98sf or 1080p24sf segmented frame signals ALT 30p Selects 1080p29 97 or 1080p30 signals ALT 48p Selects 1080p47 95 or 1080p48 signals Note ALT means press the ALT but...

Page 6: ...rns and 100 109 High GS patterns Press the Gray Scale button only to return to the default 0 100 Gray Scale patterns The Gray Scale LED will blink slowly when the Low GS or High GS mode is enabled Not...

Page 7: ...1 75 Color Bars 100 Color Bars Inverse Crosshatch 25 APL PLUGE 10 1 100 9 Window w PLUGE Inverse Overscan 2 75 Red Window 100 Red Field Dual Needle Pulse 50 APL PLUGE 20 2 101 8 Window w PLUGE User 1...

Page 8: ...nalog signals to a rate chosen specifically for each video format The Edge mode only affects analog signals It does not affect the digital video output The currently selected Output LED will blink slo...

Page 9: ...ess the Menu button to display the OSD window which is organized into three columns The left column of the OSD window currently lists six menus User Level Output Sync Misc Com Ports and Defaults Use t...

Page 10: ...button to enter the R G B values as the new color of the User Window and User Field in the Color 75 and Color 100 groups respectively The White bars in the color bar patterns are also changed to allo...

Page 11: ...g HV sync or special V sync for an oscilloscope trigger Misc Info Serial number levels and options information Com Ports RS232 Baud Baud rate selection USB Baud Baud rate selection RS232 Flow Flow con...

Reviews: