You can solve many common freezer problems easily, saving you the cost of a possible service call. 
Try the suggestions below to see if you can solve the problem before calling the service agent. 
 

Problem 

Possible Causes 

Freezer does not 
operate. 

Not plugged in. 
Circuit breaker tripped or fuse blown. 

 

Compressor turns 
on and off 
frequently. 

The room temperature is warmer than usual. 
A large number of items has been added to the freezer. The door is opened 

too often. 

The door is not closed completely. 
The temperature control is not set correctly. The door gasket does not seal 

properly. 

The freezer does not have the correct clearances. 
The freezer has recently been disconnected for a period of time. Four hours are 

required for the freezer to cool down completely. 

Temperature 
inside the freezer 
is too warm. 

Temperature  control  is  set  too  warm.  Adjust  to  a  cooler  setting  and  allow 

several hours for the temperature to stabilize. 

Door  is  kept  open  too  long  or  is  opened  too  frequently.  Warm  air  enters  the 

freezer every time the door is opened. Open the door less often. 

The door is not closed completely. 
The door gasket does not seal properly. 
A  large  number  of  warm  or  hot  items  might  have  been  stored  recently.  Wait 

until the freezer has had a chance to reach its selected temperature. 

The freezer has recently  been  disconnected for  a period of time. Four hours 

are required for the freezer to cool down completely. 

Temperature 
inside the freezer 
is too cold. 

Temperature  control  is  set  too  cold.  Adjust  to  a  warmer  setting  and  allow 

several hours for the temperature to stabilize. 

Temperature of 
external freezer 
surface is warm. 

The  exterior  freezer  walls  can  be  as  much  as  30

°

F  warmer  than  room 

temperature.  This  is  normal  while  the  compressor  works  to  transfer  heat 
from inside the freezer cabinet. 

Vibrations 

Check to be sure the freezer is level. 
Floor is uneven or weak. Freezer rocks on the floor when it is moved slightly. 

Be sure floor can adequately support freezer. Level the freezer by putting 
wood or metal shims under part of the freezer. 

The freezer is touching the wall. Move it from the wall and re-level the freezer. 
See 

Installation Instructions

The door will not 
close properly. 

The freezer is not on a level surface. The gasket is 
dirty. 

The storage basket is out of position. 

 

If you've checked the table above and find that you still need help with your appliance, call our 
Customer Service facility at 

800-932-4267

 between 9:00AM and 5:00PM ET. We will do our best to 

answer your questions. 

LIMITED WARRANTY 

Summary of Contents for VT133

Page 1: ...3 VLT74 VT103 VLT104 Owner s Manual Mode d emploi BEFORE USE PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS AVANT UTILISATION S IL VOUS PLA T LIRE ET SUIVRE LES R GLES DE S CURIT E...

Page 2: ...uct uses eco friendly hydrocarbon refrigerant and fully complies with California CARB regulations However we are required by California Law to provide the following disclosure statement in every produ...

Page 3: ...ity of Isobutane R600a These are environmentally but flammable They do not damage the ozone layer nor do they increase the greenhouse effect Care must be taken during transportation and setting up the...

Page 4: ...such as wind rain water spray or sunlight The chest freezer should not be located next to ovens grills or other sources of high heat The chest freezer must be installed with all electrical connections...

Page 5: ...bient temperatures may also cause the freezer not to perform properly Avoid locating the freezer in moist areas Plug the freezer into an exclusive properly installed grounded wall outlet Do not under...

Page 6: ...inside the unit as opposed to the air temperature itself As a result these readings may not always display the same temperature reading To Change the Set Point While the set point value is blinking pr...

Page 7: ...ter is faulty and needs to be replaced Programming the Alarms The thermometer displays the internal temperature of the unit being monitored as well as the maximum and minimum temperatures reached The...

Page 8: ...er does not overflow 6 Clean and thoroughly dry the interior of the freezer 7 Replace the drainage plug on the inside floor 8 Close the door and plug in the freezer 9 Reset the thermostat to the desir...

Page 9: ...n freezer door unnecessarily if freezer is off for several hours If a power failure occurs frozen items will stay frozen for at least 24 hours if the freezer is kept closed If the power failure contin...

Page 10: ...warm or hot items might have been stored recently Wait until the freezer has had a chance to reach its selected temperature The freezer has recently been disconnected for a period of time Four hours a...

Page 11: ...stallation installation not in accordance with electrical or plumbing codes or use of products not approved by warrantor 4 Replacement parts or repair labor costs for units operated outside the United...

Page 12: ...les Ils n endommagent pas la couche d ozone et n augmentent pas l effet de serre Lors du transport et de l installation de l appareil il faut veiller ce qu aucune pi ce du syst me de refroidissement n...

Page 13: ...areil l avant de l appareil doit tre compl tement d gag Choisissez un endroit bien ventil avec des temp ratures sup rieures 16 C 60 F et inf rieures 32 C 90 F L appareil ne doit pas tre situ c t de fo...

Page 14: ...ifornia CARB Cependant la loi californienne nous oblige fournir la d claration de divulgation suivante dans chaque produit vendu en Californie L utilisation de cet quipement est interdite en Californi...

Page 15: ...onner correctement viter de placer le cong lateur dans des zones humides Branchez le cong lateur dans une prise murale exclusive correctement install e et mise la terre Ne pas en aucun cas r duire ou...

Page 16: ...ompartiment n est pas refroidi Le voyant rouge marqu Alarm s allume galement lorsque l appareil est branch et reste allum jusqu ce que la temp rature int rieure tombe en dessous de 11 C 12 2 F Comme a...

Page 17: ...e permettra d acc l rer le processus En outre verser de l eau chaude non bouillante sur la glace gel va acc l rer la fusion Si vous devez utiliser un grattoir il ne devrait pas tre en bois ou en m tal...

Page 18: ...aisser la porte entrouverte et bloquer la ouverte si n cessaire ou avoir la porte enlev e Soyez extr mement prudent dans le cas des enfants L unit ne doit pas tre accessible aux enfants jouer Panne le...

Page 19: ...ajout e au cong lateur La porte est ouverte trop souvent La porte n est pas compl tement ferm e Le contr le de la temp rature n est pas correctement r gl Le joint de la porte ne se scelle pas correcte...

Page 20: ...g lateur Le cong lateur touche le mur D placez le du mur et remettre niveau le cong lateur Voir Instructions d installation La porte ne se ferme pas correctement Le cong lateur ne se trouve pas sur un...

Page 21: ...Unis 5 R parations de pi ces ou de syst mes r sultant de modifications non autoris es apport es l appareil 6 Le retrait et la r installation de votre appareil s il est install dans un endroit inaccess...

Reviews: