TROUBLESHOOTING

 

Before calling for assistance or service, please check this Troubleshooting section. It may save you 
the cost of a service call. If you still need help, follow the instructions below.  
 

Problem 

Cause 

Solution 

The unit is not 
cooling. 

Loose contact between the 
plug and the unit socket. 

Connect the plug firmly into the unit socket and 
data port. 

The power voltage is out of 
range. 

Check if the unit is plugged into power 
supply of 12V or 24V. 

The temperature sensor is 
malfunctioning. 

Contact a local repair center to replace the 
temperature sensor. 

The cooling 
efficiency is bad.  

The fan motor does not 
work. 

Contact a local repair center to replace the fan 
motor. 

The unit is exposed to 
direct sunlight. 

Place the unit in a shady, cool place with good 
airflow. 

The ventilator or propeller 
is blocked. 

Clean the ventilator and the propeller, and 
make sure the unit has good ventilation. 

There is a strange 
noise or vibration 
during operation. 

The unit is malfunctioning. 

To prevent breakdown, turn the unit off 
immediately and unplug it from the data 
port. Contact a local repair center. 

There is a burning 
smell or the case 
is deformed. 

The unit is malfunctioning. 

To prevent breakdown, turn the unit off 

immediately and unplug it from the data 

port. Contact a local repair center. 

LED displays “E1” 
and the unit is not 
running. 

Not enough power is being 
supplied to the unit.  

Check unit whether it’s plugged into the power 
supply of 12V or 24V, ensure that battery 
charge is not too low. 

LED displays “E2” 
and the unit is not 
running. 

The voltage being supplied 
to the unit is too high.  

Check unit whether it’s plugged into the power 
supply of 12V or 24V, ensure that input voltage 
is not too high. 

LED displays “E3” 
and the unit is not 
running. 

The temperature senor is 
disconnected or faulty. 

Check temperature sensor’s plug, or replace 
the sensor. 

 
If your appliance shows other symptoms than those described above, or if you have checked all 
items listed as the cause and the problem still exists, then call Accucold® Customer Service at 

1-888-4-MEDLAB

.

 

 
 

 

Summary of Contents for SPRF56

Page 1: ...______ Serial No ______________________ PORTABLE REFRIGERATOR FREEZER Models SPRF56 and SPRF86 User Manual BEFORE USE PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS FELIX STORCH IN...

Page 2: ...hnical Information 3 Location of Parts 4 Before your First Use 5 Installation 5 Electrical Connection 5 Setting the Temperature 6 7 Celsius Temperature Readout 7 Energy Saving Tips 7 Cleaning 7 Storag...

Page 3: ...er on when your vehicle engine is not turned on Always be sure the correct voltage and current are applied to the cooler The voltage and current are clearly marked on the manufacturer s label which ca...

Page 4: ...4 LOCATION OF PARTS...

Page 5: ...adequate ventilation 4 Never locate the unit anywhere the ambient temperature is below 0 C 32 F or above 32 C 90 F Electrical Connection This cooler can be operated from either a DC or an AC power sou...

Page 6: ...power switch to turn on the cooler You will hear the sound of the compressor starting 5 Press the UP button or the DOWN button to adjust the temperature Pressing either button with adjust the tempera...

Page 7: ...cooler Do not set the temperature colder than you require Do not open the cooler more than necessary Do not leave the lid open longer than necessary STORAGE When storing your cooler we recommend that...

Page 8: ...vibration during operation The unit is malfunctioning To prevent breakdown turn the unit off immediately and unplug it from the data port Contact a local repair center There is a burning smell or the...

Page 9: ...9 NOTES...

Page 10: ...not in accordance with electrical or plumbing codes or use of products not approved by warrantor 4 Replacement parts or repair labor costs for units operated outside the United States 5 Repairs to par...

Reviews: