background image

Important Safety Instructions

This  device  has  been  designed  to  operate  with  this  specific  Power 

 

Supply (AC / DC Adapter) which is included. Failing to do so may cause 
malfunction and may void the warranty.

Unplug this product from the power outlet and refer servicing to qualified 

service personnel under the following conditions:

  Does not function properly by following the normal operating procedures. 

  The power supply cord or power adapter is damaged.

  It’s been dropped or the case is damaged.  

  Liquid has been spilled into the unit.

  Shows a noticeable change in performance.

Basic Operation

1

.

  To begin, connect the unit to the power outlet. The detector will begin  

a self-check process. The display will read 0, which means that 

 

the equipment is ready to check the bills.

 

2

.

  Press the 

CURRENCY

 button to select the type of currency to be verified.

3

.

  Insert  the  bill  in  any  direction  to  automatically  begin  the  verification 

process.

4

.

  

The detector will verify the bill and show the denomination as 

 

confirmation that it is genuine. Its value will be added to the verified total.

5

.

  If a bill is suspicious, it will be rejected and alert the user with two  

audible warnings and the value will not be added. The error code and the 
word FAILED will appear on the screen.

Suspicious Bill Warning

This equipment checks the Magnetic (MG), Infrared (IR), Watermark 
(WM), and Ultraviolet (UV) characteristics of the bills. If any of these  
security features do not pass, an error code will be displayed. If a bill 
is suspicious, we recommend passing it at least three more times in 
different positions.

Report Function

By pressing the

 REPORT/CURRENCY

 button repeatedly, the detector will 

show the number of bills counted for each denomination and the total.

Bill Exit Direction

The verified bill can be ejected through the back of the unit or returned 
to the front. The user can select the exit direction by pressing the  

CLEAR / DIRECTION

 button.

Sensor Calibration 

If the detector is rejecting an unusual amount of bills, it may need to  

have  the  sensors  calibrated.  Print  and  cut  the  D

585

585

 IR Calibration 

 

template  in  a  regular  sheet  of  white  office  paper  (75g)  to  perform  the 

calibration. Download the template and see complete instructions from:

www.accubanker.com/pages/support/D

585

585

Bills can be rejected by the team due to different reasons:

Temperature

32° - 104° F (0° - 40° C)

Humidity

25% - 80%

Display

LCD

Processing Speed

bill/second

Power Adapter

Input:

 100 - 240 VAC 60/50 Hz

Output:

 5VDC / 2.0 A

Accepted Banknote

Paper, Polymer, etc.

Product Dimensions

5.7 x 5.1 x 3.1 

in

(14.5 x 13 x 8 

cm

)

Product Weight

1.43 

lb

 (0.65 

kg

)

Product Specifications

Error Code Messages

Bills are  

too crumpled

Bills stuck with 

adhesive tape

Ripped 

are bills

Bills are very 

stained or dirty

Wet 

are bills

ERROR

CAUSE

SOLUTION

CF

1-

1-  99

Suspicious bill, unrecognized 
infrared image 

• Ensure the bill is aligned with 

the bill guide.

• Clean the IR Sensors.

PPR

Suspicious bill, denomination 
not recognized

• Ensure the bill is aligned with 

the bill guide.

• Clean the IR Sensors.

MG

Suspicious bill, magnetic 
information unrecognized

• Ensure the bill is aligned with 

the bill guide.

• Clean the MG Sensors.

EJ

Suspicious bill, size of the bill 
is unrecognized

• Ensure the bill is aligned with 

the bill guide.

• Clean the IR Sensors.

EA

Bill not inserted correctly

• Ensure the bill is aligned with 

the bill guider.

• Verify the top is closed.

Refer to the User Guide if any error messages appear.

Maintenance

CAUTION:

  Before  performing  any  cleaning  process,  turn  off  the 

equipment  and  unplug  it.  Please  note  that  problems  or  defects 

caused by a lack of maintenance are not covered under the 
warranty.

Please  note  that  this  equipment  needs  to  be  in  a  clean,  dust-free 

environment. Refer to the user guide for complete maintenance instructions 
and recommendations.