background image

 

10 

CAL-HYPO COMMERCIAL SYSTEM LIMITED WARRANTY 

 
PPG Industries, Inc. ("PPG") warrants (subject to the below conditions) only its title to this wa-
ter treatment system equipment (the "System") and that the System will be free of defects in 
materials and workmanship for a period of twelve (12) months from its original installation 
date.  THIS IS THE ONLY REPRESENTATION OR EXPRESS WARRANTY THAT PPG 
MAKES AND ALL OTHER EXPRESS WARRANTIES UNDER STATUTE OR ARISING 
OTHERWISE IN LAW FROM A COURSE OF DEALING OR USAGE OF TRADE WITH 
RESPECT TO THE SYSTEM ARE DISCLAIMED.  ANY IMPLIED WARRANTIES EXIST-
ING AS A MATTER OF LAW SHALL NOT EXCEED THE DURATION OF THIS LIM-
ITED WARRANTY.  IN THE EVENT THE SYSTEM FAILS TO CONFORM TO THIS 
WARRANTY, PPG'S EXCLUSIVE OBLIGATION AND YOUR EXCLUSIVE REMEDY 
SHALL BE LIMITED TO, AT PPG'S OPTION, THE FURNISHING OF NEEDED RE-
PLACEMENT PARTS OR THE FURNISHING OF A NEW SYSTEM (BUT THIS DOES 
NOT INCLUDE INSTALLATION OR THE COSTS FOR INSTALLATION).  EXCEPT AS 
PROVIDED IN THE IMMEDIATELY PRECEDING SENTENCE, IN NO EVENT WILL 
PPG BE LIABLE UNDER ANY THEORY OF RECOVERY (WHETHER BASED ON NEG-
LIGENCE OF ANY KIND, STRICT LIABILITY OR TORT) FOR ANY DIRECT, INDI-
RECT, SPECIAL, INCIDENTAL, PUNITIVE, OR CONSEQUENTIAL DAMAGES IN ANY 
WAY RELATED TO ANY USE MADE OF THE SYSTEM. 
Warranty Conditions.  This Limited Warranty shall apply and be effective only if:  (i) the PPG 
Chlorinator Warranty Registration information has been completed within thirty (30) days of 
the customer’s receipt of the system via the Internet at www.accu-tab.com; (ii) the System is 
installed and operated and maintained in accordance with this manual and the instructions ac-
companying the System; (iii) you, at your cost, promptly return the System or defective part to 
such location as may be specified by PPG; and, (iv)  only PPG's Accu-Tab

®

 Blue SI

 

calcium 

hypochlorite tablets are used in the System.  If any of these conditions are not met, this Limited 
Warranty will not apply and you acknowledge and agree that your purchase of the System will 
be on an "AS-IS" basis without any warranty of any kind whatsoever having been provided by 
PPG. 
You assume all responsibility and risk and liability arising from:  (i) the unloading, installation, 
storage, handling and use of the System, including use thereof alone or in combination with 
other materials; (ii) the improper functioning or failure of unloading, installation, transportation 
or storage equipment you use, whether furnished or recommended by PPG or not; and, (iii) the 
failure to comply with laws, rules and regulations governing storage, unloading, installation, 
handling, and use of the System.  You will indemnify, hold harmless, and defend PPG from and 
against any claim, suit, damage, cost, expense, fine, liability, or cause of action whatsoever, in-
cluding reasonable attorney fees, on account of relating to, or arising out of the use, possession, 
installation or resale of the System. 
This Limited Warranty gives you specific rights, and you also may have other rights, which 
vary from jurisdiction to jurisdiction.  Some jurisdictions do not allow the exclusion or limita-
tion of incidental or consequential damages, so the above limitations or exclusions may not ap-
ply to you.  Some jurisdictions do not allow limitations on how long an implied warranty lasts, 
so the above limitation may not apply to you. 

Summary of Contents for PowerBase 3070AT

Page 1: ...ets only Do not mix Cal Hypo tablets with stabilized chlorine or bromine products or other sanitizing chemicals Fire or explosion could result Rev 04 26 10 NSF 50 The PowerBase 3070AT Chlorinator is N...

Page 2: ...or use ONLY with PPG Accu Tab Blue SI tablets utilizing the PPG patented erosion feeder technology that erodes only the bottom layer of tablets on the sieve plate while keeping tablets above the sieve...

Page 3: ...e chlorine application point with 1 1 2 PVC pipe or hose Include an isolation valve in the line 9 Plug the power cord into an 110v receptacle 10 If a chemical controller is utilized plug the controlle...

Page 4: ...4...

Page 5: ...maximum inlet flow is determined 6 Adjust flow through feeder using the discharge gate valve The chlorine delivery is determined by the flow rate through the chlorinator Use the graph above to determ...

Page 6: ...on system may develop a build up of scale This should be cleaned on a periodic basis up to twice per year If scale formation is severe more frequent cleanings may be necessary Cleaning may be accompli...

Page 7: ...hrough the blue tubing Circulate for 10 minutes 10 Open all valves to begin purging acid from system 11 Wash the walls and sieve plate of the feeder with a hose to remove all acid residue Chlorine gas...

Page 8: ...8 Electrical Drawing Base System...

Page 9: ...mpers between Terminal 1 4 Terminal 2 6 Electrical Drawing With HHL Pump Switch If a chemical controller is NOT used with the HHL Pump Switch the jumpers should be placed between Terminals 1 and 4 Ter...

Page 10: ...talled and operated and maintained in accordance with this manual and the instructions ac companying the System iii you at your cost promptly return the System or defective part to such location as ma...

Page 11: ...11...