EXS-210 STEREO MICROSCOPE 

ACCU-SCOPE

® 

SPECIFICATIONS 

Objective magnification:  1x/2x, 2x/4x, 1x/3x, 1x/2x/3x, or 1x/2x/4x

 

Viewing head: Inclined at 45 degrees, interpupillary distance range: 54

76mm 

Working distance:  57mm 

Illumination system:  Adjustable illumination for both LEDs (top and bottom) 

OPTICAL DATA 

EYEPIECE 

OBJECTIVE 

1X 

2X 

3X 

4X 

5X/22MM 

Total Magnification 

5X 

10X 

15X 

20X 

FOV (mm) 

22 

12 

10X/20mm 

Total Magnification 

10X 

20X 

30X 

40X 

FOV (mm) 

20 

10 

6.7 

15X/15mm 

Total Magnification 

15X 

30X 

45X 

60X 

FOV (mm) 

15 

7.5 

4.3 

20X/10mm 

Total Magnification 

20X 

40X 

60X 

80X 

FOV (mm) 

10 

6.5 

4.3 

3.2 

Working Distance 

57mm 

57mm 

57mm 

57mm 

Summary of Contents for EXS-210-24

Page 1: ...MANUAL EXS 210 STEREO MICROSCOPE SERIES 100 Lauman Lane Suite A Hicksville NY 11801 Tel 877 877 7274 Fax 516 801 2046 Email Info nyscopes com www microscopeinternational com LVWULEXWHG E...

Page 2: ...NT AND OPERATION CONNECTING THE POWER CORD 5 ADJUSTING INTERPUPILLARY DISTANCE 5 ADJUSTING THE DIOPTER 6 ADJUSTING THE FOCUSING TENSION 6 CHANGING THE MAGNIFICATION 7 ADJUSTING ILLUMINATION 7 OBSERVIN...

Page 3: ...semble any component including eyepieces objective housing or the focusing assembly 2 Keep the instrument clean remove dirt and debris regularly Accumulated dirt on metal surfaces should be cleaned wi...

Page 4: ...shipment UNPACKING AND COMPONENTS Your microscope arrived packed in a molded shipping carton Do not discard the carton the shipping carton should be retained for reshipment of your microscope if need...

Page 5: ...210 STEREO MICROSCOPE ACCU SCOPE 4 COMPONENTS DIAGRAM continued Indicent Top Illuminator Transmitted Bottom Illuminator Incident Top Illuminator Variable Intensity Adjustment Dial Power Cord Receptac...

Page 6: ...he way toward the front of the microscope or away from you for the Top illuminator the dial on the right side of the microscope should be turned all the way toward the back of the microscope or toward...

Page 7: ...e diopter ring on left eyepiece to focus the specimen NOTE The working distance of the microscope is 57mm the distance between the microscope objective to the top of the specimen Adjusting the Focusin...

Page 8: ...cation of eyepiece i e 3x X 10 30x Adjusting Illumination Fig 6 The EXS 210 is equipped with a rechargeable variable built in 3 way illumination system LEDs for incident top and transmitted bottom Bri...

Page 9: ...ion A slight turn of the focusing knobs may be needed to sharpen focus Recharging the Microscope Fig 8 The LED cordless rechargeable microscope is completely portable and be used indoors or outdoors i...

Page 10: ...able batteries 5 Close the trap door and place the microscope in an upright position 6 Plug the charger to the power receptacle on the back of the microscope and plug into an electrical receptacle for...

Page 11: ...Illumination system Adjustable illumination for both LEDs top and bottom OPTICAL DATA EYEPIECE OBJECTIVE 1X 2X 3X 4X 5X 22MM Total Magnification 5X 10X 15X 20X FOV mm 22 12 8 6 10X 20mm Total Magnifi...

Page 12: ...iopter adjustment is incomplete Complete diopter adjustment 2 Dirt is visible in field of view Dirt on specimen Clean specimen Dirt on eyepiece Clean eyepiece 3 The visibility of the image is poor Dus...

Page 13: ...m the date of invoice to the original end user purchaser The LED lamp is warranted for a period of two years from the date of invoice to the original end user purchaser This warranty does not cover da...

Reviews: