CALIDO1
DHW heat pump with tank
22
Note: auxiliary heat exchange coil is present only in GREEN 200 2S unit.
9.7 ELECTRICAL CONNECTIONS
Check out that the power supply meets the unit’s electric nominal data (tension, phases, frequency) reported on the technical label of the unit.
The appliance is supplied complete with power cable and Schuko plug, it is forbidden to tamper with the cable or plug; if necessary, contact the
service centre. It is advisable to check the electrical system to ensure it complies with current standards. Check that the system is suitable for
ATTENTION: The power supply must comply with the above limits, otherwise the warranty will expire immediately. Before
ATTENTION: The supply voltage must not change by more than ±10% of the nominal value. If this tolerance is not respected,
please contact our technical department.
The appliance must always be properly grounding. If the power supply is not grounded, the unit may not be connected.
Never use an extension cable to connect the unit to electric power supply.
in order to avoid a hazard. Improper movement or repair on the unit could lead to water leakage, electrical shock, injury or
To access the electrical box:
1.
2. remove the metallic cover of the electrical box unscrewing the 4 screws.
3. The unit already has a power cable connected to the electrical box. If it is necessary to disconnect it and connect a longer cable, or if it is
-
earth leakage circuit breaker is 30mA, 0.1 sec.