A111 Pulsed Coherent Radar (PCR)
Datasheet, v1.8
Page 9 of 34
2019-06-12
© 2019 Copyright by Acconeer
4
Specifications
4.1 Absolute Maximum Ratings
The below table shows the A111 absolute maximum ratings over operating temperature range, on
package, unless otherwise noted:
Parameter
Description
Min.
Max.
Unit
VIO_1
(2)
1.8 V RF power supply
0
2.0
V
VIO_2
(2)
1.8 V RF power supply
0
2.0
V
VIO_3
1.8 V digital power supply
0
2.0
V
XIN
(1)
Clock input port for crystal or reference
clock
-0.5
1.6
V
I/O
I/O supply voltage
-0.5
VIO_3+0.5
V
T
OP
Operating temperature range
-40
85
°C
T
STG
High temperature storage
150
°C
Table 4.1. Absolute maximum ratings
(1)
XIN input may not exceed 0V when ENABLE is low.
(2)
VIO_1 and VIO_2 must never exceed VIO_3.
Stresses beyond those listed in table 4.1 may cause permanent damage to the device. These are stress
ratings only and functional operation of the device at these conditions or at any other conditions
beyond those indicated under Recommended Operating Conditions is not implied. Exposure to
absolute-maximum-rated conditions for extended periods of time may affect device reliability.
4.2 Environmental Sensitivity
The below table shows the A111 environmental sensitivity:
Parameter
Standard
Max.
Unit
Storage temperature
JESD22-A103
(1)
150
(1)
ºC
Reflow soldering temperature
(1)
J-STD-020
(1)
260
ºC
Moisture Sensitivity Level
JESD22-A113
(1)
MSL3
ESD, Charge Device Model (CDM)
JS-002, Class C2
500
V
ESD, Human Body Model (HBM)
JS-001, Class 1C
1000
V
Latch-up
JESD78, Class I
Pass
Table 4.2 Environmental sensitivity
(1)
For reference only. The package is generically qualified by the manufacturer. Acconeer does not guarantee adherence to
standard.