USER MANUAL
Solar DataSnap | Sep. 30, 2021 © 2021 Acclima, Inc. https://acclima.com
Figure 20 - Time Bar Scrollbar Showing
Days
yellow scrollbar at the bottom of the time bar. The time units will
change according to the size of the scrollbar. Figures 19 and 20
show two possible scenarios.
Figure 19 - Time Bar Scrollbar Showing Months
To view a different date range in the time bar, click the ‘Graph’ menu at
the top of the screen.
•
Main Graph - Each selected sensor reading will be displayed as a
separate series in a unique color on the graph. If no data is
displayed on the graph, it is likely because the date range specified
in the time bar, falls outside the actual reading dates. To see details
for specific readings, move the mouse around the graph. A gray
vertical line will span all the visible series and a gray circle will be
displayed at the intersection of the line and each series. The circle
highlights the reading that is closest to the time indicated by the
vertical bar. The highlighted readings are displayed in a legend to
the right of the graph.
Gather Data from Micro USB Thumb Drive
The Solar DataSnap supports data collection using a USB thumb drive.
Unfortunately, at this present time the SnapView Software does not
support importing from external files, so data gathered in this way cannot
at present be used in conjunction with the SnapView Software.
To use a thumb drive to gather data
Plug in the USB thumb drive firmly into the micro-USB port. Wait a
second to allow the USB connection to stabilize and link to the drive. The
USB light should then come on and blink to indicate data flow to the thumb
drive. When the LED turns off and stays off, the data has been gathered
and the thumb drive can be removed. Do not remove the drive while in
the middle of the process! File fragmentation and data loss will occur.
Data is stored to the following folder\file structure. If the folders or files do
not exist, then the Solar DataSnap will create them. In this example, Solar