TESTING EMITTER OUTPUT

After you have addressed each Quad Eye fixture we recommend that you also test each one 
prior to installation. This can be achieved with your RDM (Remote Device Management) 
tool. Various third party DMX/RDM tools are available; Acclaim Lighting recommends the 
Swisson XMT-350 for this task.

TO TEST EMITTER OUTPUT USING THE SWISSON XMT-350

1  Connect the XMT-350 to the DMX input line of either a single fixture or multiple fixtures in 

a pre-arranged daisy chain configuration.

2  Power on the fixture(s) and the XMT-350.
3  On the XMT-350, press the 

MODE

 button, then use the arrow buttons to highlight the 

SEND

 function and press the   button to select. 

4  Use the arrow buttons to determine the DMX output:

 

Use the left and right buttons to choose the DMX address,

 

Use the up and down buttons to increase/decrease the level at the chosen address. 

Note: If you wish to send DMX values to all addresses simultaneously (rather than cycling 
through them individually), when the XMT-350 is showing address 001, press the left button 
once to change to 

ALL CHANNELS

. Now when you set the level it will affect all emitters equally.

  

Summary of Contents for Quad Eye

Page 1: ...Quad Eye User guide...

Page 2: ......

Page 3: ...TION 2 Welcome 2 Safety 2 Optional extras 3 INSTALLATION 4 Power and control wiring 5 OPERATION 6 Addressing fixtures 6 Testing emitter output 7 FURTHER INFORMATION 8 Troubleshooting 8 Specifications...

Page 4: ...table head that rotates and pivots Each Quad Eye is fully configurable using RDM Remote Device Management and can be assigned to any set of DMX addresses four per fixture Quad Eye fixtures are rated I...

Page 5: ...ting com OPTIONAL EXTRAS DMX RDM tool plus male 5pin XLR lead XMT350 Large power supplies 115 230VAC 47 63Hz input 24VDC 240W powers 11x Quad Eye fixtures APS 240 24 24VDC 480W powers 22 x Quad Eye fi...

Page 6: ...e on the reverse side of the mounting surface to keep the fixture securely in place These arms must be fully retracted as the fixture is placed into the mounting hole Quad Eye fixtures are Non IC Insu...

Page 7: ...DMX and DMX lines TIPS FOR ACHIEVING SUCCESSFUL DMX CONTROL Do not exceed a total cable length of 3 900 ft 1200m without buffering Do not exceed a total of 32 fixtures on a single line without buffer...

Page 8: ...lect The XMT 350 will search for RDM devices and after a short while the XMT 350 will display a list of all located fixtures QUAD EYE 001 MAIN QUAD EYE QUAD EYE QUAD EYE 005 009 013 PATCH OPTIONS 004...

Page 9: ...in a pre arranged daisy chain configuration 2 Power on the fixture s and the XMT 350 3 On the XMT 350 press the MODE button then use the arrow buttons to highlight the SEND function and press the but...

Page 10: ...tput by the controlling source device Check that the DMX hot and DMX cold lines on the incoming control link have not been crossed SPECIFICATIONS Color Quad color chip RGBW W 6000K Beam angle 20o stan...

Page 11: ...9 www acclaimlighting com DIMENSIONS 5 31 135mm 3 35 85mm 3 74 95mm 4 72 120mm 4 35 110 6mm 0 71 18mm...

Page 12: ...rd party items not manufactures by Acclaim lighting During the period specified above Acclaim Lighting will replace defective parts at its expense and will absorb all expenses for warranty service and...

Page 13: ......

Page 14: ...www acclaimlighting com...

Reviews: