INPUT WIRING PROTECTION
Ensure that appropriate care is taken to protect the junction where the mains and control
inputs are joined to the feed cable. An optional IP66-rated junction box is available from
Acclaim Lighting [Part #: AJBOX1] which provides separated mains and control inputs for
connection to the combined feed-in cable:
Ensure that:
•
the mains input is derived from a suitable overload-protected supply.
•
all cable access points, plus the enclosure cover are correctly sealed.
•
all local codes are followed during planning and installation.
•
only suitable cable connectors are used within the junction box.
•
connections are made, inspected and certified by a qualified electrician.
Feed cable to fixture
(use optional gland
to suit)
AC surge
protection
Internal barrier between
high and low voltage
connections
Separated DMX
and power inputs
(Ø21mm
openings - use
optional conduit
glands to suit)
WHEN TO USE AN AJBOX1
Some municipalities have specific requirements when
wiring low and high voltage cables in close proximity. Such
requirements could include the use of a barrier within the
junction box or particular minimum spacings between the
control and power cables.