Welcome to the Flood One EO range from Acclaim Lighting, a small family of aluminum 
bodied IP66-rated exterior LED flood fixtures.
The Flood One EO family fully embraces 
Acclaim Lighting’s Modular Systems 
(AMS) design standard; AMS allows 
a wider choice of internal and external options to be configured in our Los Angeles 
headquarters and delivered in industry-leading time. There are numerous emitter options, 
together with a native beam angle of 10

O

, adjustable using a range of spread lens options to 

suit your installation:

 

2700K, 3000K, 3500K or 4000K (all with Color Rendering Indexes of more than 80),

 

10º standard with 20º, 40º, 60º, 90º x 60º or 10º x 60º optional spread lenses.

Additionally, factory fitted half and full snoots allow the light output to be shaped further. 
Control is achieved using the industry standard 0-10V sink format and, with the addition of 
the optional Acclaim Lighting ZDM 6 and Aria units (see page 9), you can add remote 
wireless connectivity to the list of abilities within the Flood One EO range.  
The internal auto-sensing power supply within each unit can accept mains inputs between 
100 to 277VAC at 50 or 60Hz. Total power consumption is just 60W peak, 55W steady state. 

SAFETY

 

When fixtures are mounted off-ground, ensure they are securely fitted to an appropriate 
mounting surface.  

 

Ensure that the power input is supplied from a correctly fused, earthed and 
environmentally protected location.

MAINTENANCE

CAUTION: Always isolate mains power before starting maintenance operations.

 

Ensure that all mounting (and device) screws/bolts are fully tight and free of corrosion.

 

Ensure there is no deformation to the housing, lenses or fixing points.

 

Check that all power supply cables are free from physical damage or material fatigue.

 

Use only genuine spare parts supplied by Acclaim Lighting.

CLEANING

 

Use a moist, lint-free cloth when cleaning each fixture.

 

Never use alcohol or solvents.

Summary of Contents for Flood One EO Series

Page 1: ...Flood One EO User guide...

Page 2: ......

Page 3: ...s 4 INSTALLATION 5 Tilt adjustment 5 Using a tenon mount 6 Using a pipe clamp 7 Power and control wiring 8 Input wiring protection 8 Optional DMX operation 9 Optional wireless DMX operation 9 Optional...

Page 4: ...ormat and with the addition of the optional Acclaim Lighting ZDM 6 and Aria units see page 9 you can add remote wireless connectivity to the list of abilities within the Flood One EO range The interna...

Page 5: ...3 www acclaimlighting com SUPPLIED ITEMS Standard model Half snoot model standard model plus FBHSG Full snoot model standard model plus FBFSG...

Page 6: ...ighting com OPTIONAL ACCESSORIES Tenon mounts 2 pipe 2 51 56mm inner dia TM2 4 pipe 4 13 105mm inner dia TM4 Pipe clamps each can mount 1 or 2 fixtures 2 pipe 2 51 56mm inner dia PC2 4 pipe 4 13 105mm...

Page 7: ...the center line see page 13 The yoke has a thickness of 0 24 6mm Select bolts or screws not supplied that fit the yoke holes correctly and are particularly suited to the mounting surface Optional ten...

Page 8: ...of the pole Tenon mounts must NEVER be used to hang a Flood One EO below a pole TO USE A TENON MOUNT 1 Slide the tenon mount onto the vertical pole and secure using the two bolts on the side 1 4 6mm A...

Page 9: ...h side to join the two halves see below about the correct use of the supplied washers 4 Tighten the two main bolts evenly until the clamp is held firmly in place 5 Use one of the two smaller bolts wit...

Page 10: ...inputs are joined to the fixture s feed cables Ensure that the mains input is derived from a suitable overload protected supply the junction boxes have an environmental rating of at least IP66 all cab...

Page 11: ...claim Lighting ZDM 6 device is available to perform the necessary signal conversion OPTIONAL WIRELESS DMX OPERATION VIA ARIA UDM W In addition to performing DMX to 0 10V signal conversions the optiona...

Page 12: ...VIA ZDM 6 ARIA UDM W Using a combination of Acclaim Lighting ZDM 6 Aria and UDM W units it is possible to transmit a 0 10V input wirelessly over distances up to 2600 feet 792m line of sight to the Fl...

Page 13: ...TION TROUBLESHOOTING LUMINAIRE DOESN T TURN ON Check that power is correctly applied to the fixture and that there is no damage to the power input cord Check that the 0 10V hot and cold lines on the i...

Page 14: ...r and 0 10V local to each fixture Power input 100 277VAC 50 60Hz Power consumption 60W Housing Die cast aluminum glass lens optional marine coating available Mounting Surface mount yoke included Fixtu...

Page 15: ...ng com DIMENSIONS STANDARD MODEL 10 63 270mm 11 81 300mm 13 07 332mm 2 13 54mm 2 13 54mm 5 71 145mm 4 25 108mm 7 01 178mm 3 86 98mm 10 63 270mm 11 81 300mm 5 71 145mm 4 25 108mm 6 26 159mm 13 07 332mm...

Page 16: ...ghting com HALF SNOOT MODEL 10 63 270mm 11 81 300mm 5 71 145mm 4 25 108mm 7 83 199mm 13 07 332mm 10 63 270mm 11 81 300mm 13 07 332mm 2 13 54mm 2 13 54mm 0 47 12mm 6 3 160mm 5 71 145mm 4 25 108mm 7 01...

Page 17: ...ghting com FULL SNOOT MODEL 10 63 270mm 11 81 300mm 5 71 145mm 4 25 108mm 7 83 199mm 13 07 332mm 10 63 270mm 11 81 300mm 13 07 332mm 2 13 54mm 2 13 54mm 0 47 12mm 6 3 160mm 5 71 145mm 4 25 108mm 7 01...

Page 18: ...rd party items not manufactures by Acclaim lighting During the period specified above Acclaim Lighting will replace defective parts at its expense and will absorb all expenses for warranty service and...

Page 19: ......

Page 20: ...www acclaimlighting com...

Reviews: