FAULT PROTECTION
In the case of a short circuit, open circuit, reversed polarity or battery voltage
below 7.5V ± 0.5, the charger will turn off the electronic system and revert to
standby mode.
• The “Fault” (!) LED will illuminate.
The fault must be identified and resolved before any of the charging modes
are initiated.
OVERHEATING PROTECTION
If the charger becomes too hot during the charging process or due to
extreme ambient temperatures the power output is automatically reduced to
a trickle charge to protect the unit. Once the temperature drops the charger
will increase the power output automatically.
3
This mode is mainly for charging large batteries with a capacity of
12-80Ah in cold conditions or for charging several AGM batteries
with a capacity over 20Ah.
1. Press the MODE button until the LED adjacent to the ice crystal
symbol is illuminated.
• Charging will start and the 'charging' LED will illuminate.
• When the battery is fully charged the 'charging' LED will
extinguish and the 'fully charged' LED will illuminate.
4
This mode is mainly for charging all types of 6V batteries with a
capacity of 12-80Ah.
1. Press the MODE button until the LED adjacent to the 6V battery
symbol is illuminated.
• Charging will start and the 'charging' LED will illuminate.
• When the battery is fully charged the 'charging' LED will
extinguish and the 'fully charged' LED will illuminate.
5
This mode is for lead calcium batteries or a battery below 10.5V with
no capacity to absorb charging current.
• The charger will raise the output voltage up to 17 volts. The
“Cal” LED will illuminate and flash, the charging LED will
illuminate.
• If the battery cannot be recovered within 2 hours the
“Fault” (!) LED will illuminate. The battery may require
replacing.